9.1 Cables for the SGMMV Servomotors
9.1.1 System Configurations
9-2
9.1
Cables for the SGMMV Servomotors
9.1.1
System Configurations
The cables shown below are required to connect a Servomotor to a SERVOPACK.
Note: 1. If the cable length exceeds 20 m, be sure to use a Relay Encoder Cable.
2. If you use a Servomotor Main Circuit Cable that exceeds 20 m, the intermittent duty zone in the torque-
motor speed characteristics will become smaller because the voltage drop increases.
3. Refer to the following manual for the following information.
•
Cable dimensional drawings and cable connection specifications
•
Order numbers and specifications of individual connectors for cables
•
Order numbers and specifications for wiring materials
Σ
-7-Series AC Servo Drive Peripheral Device Selection Manual
(Manual No.: SIEP S800001 32)
Encoder Cable of 20 m or Less
Encoder Cable of 30 m to 50 m (Relay Cable)
SERVOPACK
Encoder Cable
Battery Case
(Required when an
absolute encoder is used.)
Servomotor
Main Circuit Cable
Servomotor
Servomotor-end
Cable
Encoder-end
Cable
SERVOPACK
Cable with a Battery
(Required when an
absolute encoder is used.)
Cable with Connectors
on Both Ends
Encoder-end Cable
Servomotor-end
Cable
Servomotor Main
Circuit Cable
Servomotor
Relay Encoder Cable