6.10 Software Reset
6.10.1 Preparations
6-44
6.10
Software Reset
You can reset the SERVOPACK internally with the software. A software reset is used when
resetting alarms and changing the settings of parameters that normally require turning the
power supply to the SERVOPACK OFF and ON again. This can be used to change those
parameters without turning the power supply to the SERVOPACK OFF and ON again.
6.10.1
Preparations
Confirm that the following conditions are met before you perform a software reset.
•
The servo must be OFF.
•
The motor must be stopped.
6.10.2
Applicable Tools
The following table lists the tools that you can use to perform a software reset.
1. Always confirm that the servo is OFF and that the motor is stopped before you start a soft-
ware reset.
2. This function resets the SERVOPACK independently of the host controller. The SERVO-
PACK carries out the same processing as when the power supply is turned ON and out-
puts the ALM (Servo Alarm) signal. The status of other output signals may be forcibly
changed.
3. When you execute a software reset, the SERVOPACK will not respond for approximately
five seconds.
Before you execute a software reset, check the status of the SERVOPACK and Servomo-
tor and make sure that no problems will occur.
Information
Tool
Function
Operating Procedure Reference
Digital Operator
Fn030
Σ
-7-Series Digital Operator Operating Manual (Manual
No.: SIEP S800001 33)
S
Setup - Software Reset