7.5 General I/O Signal Assignment
7-38
JANCD-XIO02 (CN10 Connector) I/O Allocation and Connection Diagram
JANCD-XTU01
CN26
-9
-10
-7
-8
A20
B20
A19
B19
A18
B18
A17
B17
A16
B16
A15
B15
A14
B14
A13
B13
A12
B12
A11
B11
A10
B10
A9
B9
A8
B8
A7
B7
A6
B6
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
JZNC-XIU01
YASNAC-XRC
CN10 Connector
B1
A1
B2
A2
B3
A3
B4
A4
B5
A5
B6
A6
B7
A7
B8
A8
B9
A9
B10
A10
B11
A11
B12
A12
B13
A13
B14
B15
A14
A15
B16
B17
A16
A17
B18
A18
B19
A19
B20
A20
RLY
RLY
RLY
RLY
RLY
RLY
+24VU
* means internal relay
means
JANCD-XIO02
2040
2041
2042
2043
2044
2045
2046
2047
3040
3041
3042
3043
3044
3045
IN08
0
24
VU
0
24
VU
+24VU
+24VU
+24VU
+24VU
FG
IN
IN
IN
IN
IN
IN
IN
IN
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
3046
3047
IN01
General Input
IN02
IN03
IN04
IN05
IN06
IN07
OUT01-
General Output
OUT01+
OUT02-
OUT02+
OUT03-
OUT03+
OUT04-
OUT04+
OUT05-
OUT05+
OUT06-
OUT06+
OUT07-
OUT07+
RLY
RLY
2
1
4
3
6
5
8
7
10
9
12
11
14
13
16
15
18
17
20
19
22
21
24
23
26
25
28
30
27
29
32
34
31
33
36
35
38
37
40
39
OUT08-
OUT08+
OUT
OUT
OUT
OUT
+24VU
RLY
Each Point
24VDC
8mA max.
Each Point
24VDC
500mA max.
Internal
Power Supply
+24 V
0
24
V
(24V,1A)
+24 VE
0
24
VE
0
24
VU
Logical
Number
Signal
0
24
VU
0
24
VU
0
24
VU
0
24
VU
* Remove Jumper-pin between CN26-9 and -7, CN26-10 and -8
when a external power supply is used.
Connector Terminal Converter
(Optional)
Model:PX7D-40V6-R
Connector
Number
Terminal
Number
Содержание Motoman UP6
Страница 4: ...UP6 Manipulator Manual ii MOTOMAN NOTES...
Страница 65: ...11 1 S Axis Parts List 11 1 11 Parts List 11 1 S Axis Parts List...
Страница 67: ...11 2 L U Axis Driving Unit 11 3 11 2 L U Axis Driving Unit...
Страница 69: ...11 3 R Axis Driving Unit 11 5 11 3 R Axis Driving Unit...
Страница 71: ...11 4 Wrist Unit 11 7 11 4 Wrist Unit...
Страница 73: ......
Страница 82: ...viii...
Страница 94: ...1 4 Equipment Configuration 1 12...
Страница 108: ...3 8 Open Phase Check 3 8...
Страница 131: ...20...
Страница 146: ...xiv...
Страница 147: ...Setup Diagnosis...
Страница 148: ......
Страница 150: ...1 2...
Страница 158: ...2 1 Protection Through Security Mode Settings 2 8...
Страница 256: ...3 17 File Initialize 3 98...
Страница 278: ...4 2 Addition of Base and Station Axis 4 22...
Страница 296: ...5 6 Position Data When Power is Turned ON OFF 5 18...
Страница 297: ...Hardware...
Страница 298: ......
Страница 308: ...6 4 Equipment Configuration 6 10...
Страница 359: ...Maintenance...
Страница 360: ......
Страница 368: ...8 8 Open Phase Check 8 8...
Страница 388: ...9 4 Recommended Spare Parts 9 20...
Страница 389: ...Alarm Error...
Страница 390: ......
Страница 462: ...11 1 Error Message List 11 18...
Страница 463: ......
Страница 466: ......
Страница 530: ......
Страница 531: ......
Страница 533: ......
Страница 534: ......
Страница 535: ......
Страница 536: ......
Страница 537: ......
Страница 538: ......
Страница 539: ......
Страница 540: ......
Страница 541: ......
Страница 542: ......
Страница 543: ......
Страница 544: ......
Страница 545: ......
Страница 546: ......
Страница 547: ......
Страница 548: ......
Страница 549: ......
Страница 550: ......
Страница 551: ......
Страница 552: ......
Страница 553: ......
Страница 554: ......
Страница 555: ......
Страница 556: ......
Страница 557: ......
Страница 558: ......
Страница 559: ......
Страница 560: ......
Страница 561: ......