No.
(Addr.
Hex)
Name
Description
Values
Page
F1-37
(3BD)
PG 2 Signal Selection
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
V/f w PG
0: A pulse detection
1: AB pulse detection
Default: 0
Range: 0, 1
<1> Default setting is determined by parameter A1-02, Control Method Selection.
u
F2: Analog Input Card (AI-A3)
No.
(Addr.
Hex)
Name
Description
Values
Page
F2-01
(38F)
Analog Input Option Card
Operation Selection
All Modes
0: Option card input terminals V1, V2, and V3 replace drive input terminals
A1, A2, and A3.
1: Input signals to terminals V1, V2, and V3 are added together to create the
frequency reference.
Default: 0
Range: 0, 1
F2-02
(368)
Analog Input Option Card
Gain
All Modes
Sets the gain for the input signal to the analog card.
Default: 100.0%
Min.: -999.9
Max.: 999.9
F2-03
(369)
Analog Input Option Card
Bias
All Modes
Sets the bias for the input signal to the analog card.
Default: 0.0%
Min.: -999.9
Max.: 999.9
u
F3: Digital Input Card (DI-A3)
No.
(Addr.
Hex)
Name
Description
Values
Page
F3-01
(390)
Digital Input Option Card
Input Selection
All Modes
0: BCD, 1% units
1: BCD, 0.1% units
2: BCD, 0.01% units
3: BCD, 1 Hz units
4: BCD, 0.1 Hz units
5: BCD, 0.01 Hz units
6: BCD customized setting (5-digit), 0.02 Hz units
7: Binary input
When the digital operator units are set to be displayed in Hertz or user-set units
(o1-03 = 2 or 3), the units for F3-01 are determined by parameter o1-03.
Default: 0
Range: 0 to 7
F3-03
(3B9)
Digital Input Option DI-A3
Data Length Selection
All Modes
0: 8 bit
1: 12 bit
2: 16 bit
Default: 2
Range: 0 to 2
u
F4: Analog Monitor Card (AO-A3)
No.
(Addr.
Hex)
Name
Description
Values
Page
F4-01
(391)
Terminal V1 Monitor
Selection
All Modes
Sets the monitor signal for output from terminal V1. Set this parameter to the
last three digits of the desired U
o
-
oo
monitor. Some U parameters are
available only in certain control modes.
Default: 102
Range: 000 to 999
F4-02
(392)
Terminal V1 Monitor Gain
All Modes
Sets the gain for voltage output via terminal V1.
Default: 100.0%
Min.: -999.9
Max.: 999.9
A.8 F: Options
YASKAWA ELECTRIC SIEP YEAHHP 01B YASKAWA AC Drive – A1000 HHP Programming Manual
263
A
Parameter List