6
2. Before operating the Equipment
Precautions when installing the Equipment
1. Choose proper place for installation
Do not install this Equipment in the place where:
・
the location is rough, dirty or un-leveled.
・
flammable gas, explosive gas or corrosive gas will be generated.
・
ambient temperature will be more than 35
℃
or less than 5
℃
.
・
ambient temperature will fluctuate.
・
liquid may splash
・
there is excessive humidity and dusty.
・
there is direct sunlight.
・
there is constant vibration.
・
outside the building.
・
power supply is instable.
・
Busy places or other places that safety cannot always be assured.
Install the Equipment(s) at the place with sufficient space as specified as below
2. Install the Equipment on leveled location.
Install this Equipment on leveled floor. If it is installed on rough and/or slope floor, vibration or
noise will be occurred, and unexpected trouble and malfunction may be happened.
Weight of this Equipment is as follows:
The container weight is approx. 29kg for FP102, approx. 43kg for FP302/312, and approx. 51kg
for FP412.
Use cargo handling equipment for carrying and installation. Two or more people shall be
necessary when transporting by humans.
3. Implement safety measures when installing the unit.
Earthquakes or unexpected shocks may cause the unit to fall or move and cause a personal
injury. We recommend implementing safety measures such as installing the unit at a place with
minimum traffic.
Some parts of the unit may be hot during operation. It is extremely dangerous to touch a hot
surface, which may cause burning. We recommend installing appropriate fences around the
installation site.
4. Implement appropriate safety measures after installation.
May be injured by moved and/or fallen this Equipment down by earthquake and/or unexpected
impact.
Implement appropriate measures against falling down for safety.
Min 30cm
Min 30cm
Min 30cm
Min 1m
Содержание FP102
Страница 67: ...64 12 Wiring diagram FP102 Wiring diagram Dotted line means optional parts ...
Страница 68: ...65 12 Wiring diagram FP302 Wiring diagram Dotted line means optional parts ...
Страница 69: ...66 12 Wiring diagram FP312 Wiring diagram Dotted line means optional parts ...
Страница 70: ...67 12 Wiring diagram FP412 Wiring diagram Dotted line means optional parts ...