4
1. Safety Precautions
Residual risk list
List of residual risks (Instructions for avoiding risks)
This list summarizes residual risks to avoid personal injuries or damages to properties during or
related to the use of the product.
Be sure to fully understand or receive instructions on how to use, maintain and inspection of the
product before starting operation.
During or on carrying-in or installation
№
Degree
of risks
Details of risks
Protective measures to be implemented
by the machine users
Relevant
sections
(1)
Caution
Injury
Use cargo handling equipment for carrying
and installation. Two or more people shall be
necessary when transporting by humans.
Section 2.2
(2)
Warning
Fire or electrical
shock
Carefully select an installation site and take
care for the installation environment.
Section 2.1
(3)
Caution
Injury
Install on a level surface.
Section 2.2
(4)
Caution
Injury
Implement safety measures for installation.
Section 2.3
(5)
Caution
Injury
Implement appropriate safety measures after
installation.
Section 2.4
(6)
Warning
Fire
Assure sufficient ventilation for the unit.
Section 2.5
(7)
Warning
Fire or electrical
shock
Do not use the unit at a place that may be
subject to splashes of liquid.
Section 2.6
(8)
Warning
Explosion or fire
Do not use the unit in a flammable or an
explosive atmosphere.
Section 2.7
(9)
Warning
Fire or electrical
shock
Connect the power supply to the dedicated
distribution board.
Section 2.8
(10)
Warning
Fire or electrical
shock
Take care for handling of the power cord.
Section 2.9
(11)
Warning
Fire or electrical
shock
Be sure to connect the ground wire.
Section 2.10
Section 2.11
(12)
Warning
Fire or electrical
shock
Do not disassemble nor modify the
Equipment.
Section 2.12
During operation
№
Degree of
risks
Details of risks
Protective measures to be implemented
by the machine users
Relevant
sections
(13)
Warning
Explosion and
fire
Do not use an explosive or combustible
substance.
Section 5.1
(14)
Warning
Fire
Do not use a resin container.
Section 5.9
(15)
Warning
Fire or electrical
shock
Immediately turn the ELB off when an
abnormality should occur.
Section 5.3
(16)
Warning
Fire, electrical
shock or burning
Do not put any foreign objects in the unit.
Section 5.21
(17)
Warning
Burning
Take extreme care for handling of specimens
after operation at a high temperature.
Section 5.15
(18)
Warning
Burning
Take extreme care when opening the door
during operation at a high temperature.
Section 5.12
Section 5.13
(19)
Warning
Burning
Do not touch any hot surfaces.
Section 5.12
Section 5.15
Содержание FP102
Страница 67: ...64 12 Wiring diagram FP102 Wiring diagram Dotted line means optional parts ...
Страница 68: ...65 12 Wiring diagram FP302 Wiring diagram Dotted line means optional parts ...
Страница 69: ...66 12 Wiring diagram FP312 Wiring diagram Dotted line means optional parts ...
Страница 70: ...67 12 Wiring diagram FP412 Wiring diagram Dotted line means optional parts ...