33
8. TROUBLESHOOTING
Error Codes
Possible error messages are outlined below.
Power output to heater is stopped and users are notified of abnormalities by a corresponding error code
on the display. Make note of the code, turn off power and call for service, if necessary.
Error Code
Cause/Solution
Er01
Temperature sensor
error
Temperature sensor faulty or severed from
circuit.
Check/replace the sensor.
Restart to clear error.
Er06
Overheat
Overheating prevention device has been
activated
by
overheating,
or
by
a
temperature control error.
Restart to clear error.
If restarting does not clear error, the control
board may need replacing. Call for service.
Er15
Memory error
Setting value memory error.
Replace memory board.
Blank Display
Thermal fuse thrown
Thermal fuse has been thrown.
Replace fuse.
Call for service.