Ⅶ. PERIODIC INSPECTION

Generally speaking, it is important not to exert external stress to keep life and reliability of the instrument for a 
long time.
Proper use of this instrument will ensure its faultless service over many years without any necessity of periodic 
lubrication.
However, it is recommended that it is subjected to periodic inspection (calibration) once a year.

Ⅷ. PRODUCT WARRANTY

Warranty Period

This product warranty is valid for one year from the date of delivery to a place specifi ed by an ordering party who 
has transacted directly with Yamamoto Electric Works Co., Ltd.

Coverage

If a product breaks down due to a reason for which we are responsible during the warranty period and you return 
the product to us, we will either repair or replace the product free of charge.
This warranty does not cover:
(1)  Usage of the product under any inappropriate conditions or environment contrary to what is described in our 

product catalog, specifi cations or manual.
Handling or usage of the product other than as described in our product catalog, specifi cations or manual.

(2) Breakdown due to a reason other than a fault within our product.
(3) Any product that has been modifi ed or repaired by a party other than us.
(4)  Any breakdown due to a reason that was not foreseeable based on scientifi c and technical standards applied at 

the time of shipment.

(5) Any breakdown due to a reason not attributable to us such as a natural calamity or other disaster.

These terms of warranty represent our entire liability with respect to the product, and we shall have no liability 
for any other loss arising in connection with a breakdown of the product.

*This product warranty is only valid within Japan.

This document is a translation from the original Japanese version, and the original Japanese version has priority 
over this translation.
Be sure to refer to the original Japanese for the details of this warranty.

<Prior notice>

The  specifi cations  and  description  of  the  product  explained  in  this  instruction  manual  may  be  subject  to 
change without prior notice because of modifi cation and the like.

Содержание MS65F

Страница 1: ...I N S T R U C T I O N M A N U A L 653 0031 1 Nishi shiriike cho Nagata ku Kobe Japan TEL 078 631 6000 FAX 078 631 6020 READ THE INSTRUCTION MANUAL RoHS Compliant...

Страница 2: ...Caution of piping 6 7 Installation position 6 SETTING OF PRESSURE 1 Switch contact con guration 7 2 Setting of upper limit lower limit 7 3 Reset time 8 ABOUT BUILT IN MICRO SWITCH 1 Material of conta...

Страница 3: ...instrument The instrument is measurable for air and non corrosive gas only The machine is exclusive use of dry air 90 RH or less Using measuring the water or oil it may be damaged and causes the accid...

Страница 4: ...ce pressures Materials of pressure receiving element Pa kPa 60D 10 60 0 01 0 06 2 0 Pa 15 0 Pa Polyester lm 120D 20 120 0 02 0 12 4 0 Pa 20 0 Pa 300D 50 300 0 05 0 3 8 0 Pa 40 0 Pa 600D 100 600 0 1 0...

Страница 5: ...de 10 10 to 50 Hz Acceleration 39 m s2 each two hours on triaxial directions 100 m s2 each six times on triaxial direction Between each terminal and case 20 M or more 500 V DC megger Between each term...

Страница 6: ...trical load type The general electrical load type is decreased contact reliability refer to p 8 The withstanding pressure of the pressure receiving element means The max pressure under which the diaph...

Страница 7: ...nt of negative pressure Connect the tube to the low pressure side piping connector blue or L The high pressure port red or H should be opened to atmosphere but do not remove the piping connector c Mea...

Страница 8: ...it once in a while After the cleaning of the tank check that the air tightness is fully kept c Measurement of high temperature gases In the pressure measurement of high temperature gas use the pressur...

Страница 9: ...pressure the other is called lower limit setting type type L which is adjusted on reset pressure Be careful about the difference between the upper and lower limit setting switched and also understand...

Страница 10: ...contact for low electrical load cross point contact Magni ed drowing of contact for general load small rivet contact point 2 Contact material and applicable mecanism for low voltage and low current c...

Страница 11: ...ive force of inductive load by diode and avoid to apply high voltage to inbetween the contacts This method makes the return time of inductive load slower Choose the diode rated current is more than lo...

Страница 12: ...acid and it may also cause electrical contact failure or malfunction of switches b Silicone gas If the gas to be measured contains silicon produced from silicon contained in oil grease filling agent...

Страница 13: ...ain to x Replacement of air lter In case of using model with air lter MS65F depending on amount of work conduct disassembly and clean out once in 2 years periodically and replace lters and packings wi...

Страница 14: ...rument life For vinyl or plastic tube For metal tube Product code FG VT6 S Product code FG MT6 S T joint For vinyl or plastic tube Product code TVT6 4 6 For branching different I D 6 and 4 Product cod...

Страница 15: ...og speci cations or manual Handling or usage of the product other than as described in our product catalog speci cations or manual 2 Breakdown due to a reason other than a fault within our product 3 A...

Отзывы: