Ⅰ. PRECAUTIONS

INTRODUCTION

Thank you very much for purchasing of "MANOSTAR SWITCH MS65, MS65F".

!

Caution

To ensure your safety in using this instrument :

・  Be sure to read the instruction manual carefully before using the instrument so that you 

can use it properly. 
Wrong use may result in failure of the instrument and lead to its damage and accident. This 
manual should be kept in a proper place so that you can refer to it any time you need.

!

Warning

・  Do not use this instrument where fl ammable gas is present. 

The  instrument  is  not  explosion-proof.  Do  not  use  the  instruments  in  the  circumstance  where 
fl ammable gas is present. It may cause explosion.

・  Do not use the instrument at the place where corrosive gas is present. 

The  instrument  is  not  corrosion  resistance  construction.  Measuring  corrosive  gas  may  corrode  the 
receiving element and housing material of the instrument. It is expected that corrosive gas leaked out 
of the instrument will harm a person.

・  Do not apply the pressure to the instrument more than it can withstand. 

The  diaphragm  and  the  retainer  are  broken  if  the  pressure  exceeding  withstanding  pressure  of  the 
pressure receiving element is applied to the instrument. The case body of the instrument is broken if 
the pressure exceeding withstanding pressure of the instrument body is applied to the instrument.

・  The instrument is measurable for air and non-corrosive gas only. 

The machine is exclusive use of dry air (90% RH or less). Using measuring the water or oil it may be 
damaged and causes the accident.

・  Avoid using where the instrument is subject to many vibration and impact. 

Using  the  instrument  where  intensifi ed  vibration  and  impact  may  be  damaged  the  instrument.  It  is 
expected that gas leaks of the instrument which harms a parson.

・  Do not exceed rated voltage in using. 

Using the instrument by exceeding rated voltage may cause fi re or electric shock.

・  Wire correctly. 

Incorrect wiring may cause fi re.

・  Do not exceed rated surrounding temperature, humidity and altitude in use. 

Using the instrument by exceeding rated surrounding temperature and humidity and altitude it may be 
damaged and cause the accident.

・  Do not disassemble or reconstruct the instrument. 

It may void the warranty.

!

Caution

・  As  to  where  to  install  and  how  to  install  this  instrument,  be  sure  to  follow  the  instruction  manual 

provided so as to ensure a proper method.

・ Use the instrument indoors.

・  In case of not being installed in dry and well-kept clean locations, the instrument must be enclosed in 

box of min. Protection degree IP54.

・  Do not use organic solvent for cleaning. 

Use a cloth soaked with water-diluted neutral detergent to wipe the surface of a product. Using of 
organic solvent causes damage on the surface.

・  

Dropping the product 

If the product is dropped onto a desk or fl oor, not only its exterior but also interior mechanism is 
broken.

Содержание MS65F

Страница 1: ...I N S T R U C T I O N M A N U A L 653 0031 1 Nishi shiriike cho Nagata ku Kobe Japan TEL 078 631 6000 FAX 078 631 6020 READ THE INSTRUCTION MANUAL RoHS Compliant...

Страница 2: ...Caution of piping 6 7 Installation position 6 SETTING OF PRESSURE 1 Switch contact con guration 7 2 Setting of upper limit lower limit 7 3 Reset time 8 ABOUT BUILT IN MICRO SWITCH 1 Material of conta...

Страница 3: ...instrument The instrument is measurable for air and non corrosive gas only The machine is exclusive use of dry air 90 RH or less Using measuring the water or oil it may be damaged and causes the accid...

Страница 4: ...ce pressures Materials of pressure receiving element Pa kPa 60D 10 60 0 01 0 06 2 0 Pa 15 0 Pa Polyester lm 120D 20 120 0 02 0 12 4 0 Pa 20 0 Pa 300D 50 300 0 05 0 3 8 0 Pa 40 0 Pa 600D 100 600 0 1 0...

Страница 5: ...de 10 10 to 50 Hz Acceleration 39 m s2 each two hours on triaxial directions 100 m s2 each six times on triaxial direction Between each terminal and case 20 M or more 500 V DC megger Between each term...

Страница 6: ...trical load type The general electrical load type is decreased contact reliability refer to p 8 The withstanding pressure of the pressure receiving element means The max pressure under which the diaph...

Страница 7: ...nt of negative pressure Connect the tube to the low pressure side piping connector blue or L The high pressure port red or H should be opened to atmosphere but do not remove the piping connector c Mea...

Страница 8: ...it once in a while After the cleaning of the tank check that the air tightness is fully kept c Measurement of high temperature gases In the pressure measurement of high temperature gas use the pressur...

Страница 9: ...pressure the other is called lower limit setting type type L which is adjusted on reset pressure Be careful about the difference between the upper and lower limit setting switched and also understand...

Страница 10: ...contact for low electrical load cross point contact Magni ed drowing of contact for general load small rivet contact point 2 Contact material and applicable mecanism for low voltage and low current c...

Страница 11: ...ive force of inductive load by diode and avoid to apply high voltage to inbetween the contacts This method makes the return time of inductive load slower Choose the diode rated current is more than lo...

Страница 12: ...acid and it may also cause electrical contact failure or malfunction of switches b Silicone gas If the gas to be measured contains silicon produced from silicon contained in oil grease filling agent...

Страница 13: ...ain to x Replacement of air lter In case of using model with air lter MS65F depending on amount of work conduct disassembly and clean out once in 2 years periodically and replace lters and packings wi...

Страница 14: ...rument life For vinyl or plastic tube For metal tube Product code FG VT6 S Product code FG MT6 S T joint For vinyl or plastic tube Product code TVT6 4 6 For branching different I D 6 and 4 Product cod...

Страница 15: ...og speci cations or manual Handling or usage of the product other than as described in our product catalog speci cations or manual 2 Breakdown due to a reason other than a fault within our product 3 A...

Отзывы: