Before  using  this  instrument,  make  sure  if  it  is  the  type  that  you  requested  and  meets  the  demand  of  the 
environment, pressure and piping conditions where it is used, by specifi cation.

1. Caution of service condition

a)  Do  not  use  the  instrument  in  a  place  subjected  to  direct  sunlight,  vibration  or  shock,  or  excessive 

moisture. In particular, vibration and shock to the instrument should shorten its life.

b) Use under the medium and ambient temperature from - 10 to + 50 ℃ .

c)  The instrument is not waterproof. Do not use it in a place subjected to rain, or other splashing water.

d)  The  instrument  cannot  be  installed  outdoors  without  an  appropriate  protection.  If  outdoor  installing  is 

required, the instrument should be housed in a box of drip-proof type for outdoor use.

e) In installing the instrument, select the place where the ground is smooth and fl at.

2. Installation of MS65, MS65F

Panel cut size

3. Pressure of measurement and connection of piping

a)  Measurement of positive pressure

Connect the tube to the high pressure side piping connector (indicated by red color or letter H). The 
lower pressure port (blue or L) should opened to atmosphere, but do not remove the piping connector.

b)  Measurement of negative pressure

Connect the tube to the low pressure side piping connector (blue or L). The high pressure port (red or H) 
should be opened to atmosphere, but do not remove the piping connector.

c)  Measurement of differential pressure

Connect the tube from the high pressure piping connector to the high pressure port (red or H) and from 
the low pressure piping connector to the low pressure port (blue or L).

4. Connectors and piping material

a) Connectors for vinyl or plastic tube (VT, VL, VK connectors)

These are connectors for vinyl, plastic or rubber tubes. Be sure to use I.D. 6 and thickness of 1 mm or 
more. However, the vinyl or plastic tube (2 or more wall thickness) with enough withstanding pressure 
(including vacuum pressure) is required when the instrument range or the line pressure is higher more 
than 50 kPa.

b)  Connectors for metal tube (MT, ML, MK connectors)

These piping connectors can be connected to metal
tube made from copper and aluminum and so on.
(O.D. 6, tolerannce ± 0.1, ring joint type)
When this connector is connected to hard plastic
tube (O.D. 6, I.D. 4), remove the sleeve made of
bress and use the resinous inner sleeve set (XIN6 ×
4) that is the optional accessory.

MS65

MS65F

!

Caution

Tighten the piping 
connectors with the torque 
of 1 N・m.
Do not apply excessive 
torque more than 
necessary, otherwise it 
will damage the instrument 
body.

Inner sleeve set 

for plastic tube

Product code XIN6X4

ᵧᶌᶌᶃᶐίᶐᶃᶑᶇᶌᵇ

ᵱᶊᶃᶃᶔᶃίᶐᶃᶑᶇᶌᵇ

ᵮᶊᵿᶑᶒᶇᶁᴾᶒᶓᶀᶃ

ᵔᵑᶠᵎᵌᵑ

ᵔᵑᶠᵎᵌᵑ

ᵒᶣ᷑ᵓᴾᶆᶍᶊᶃᶑᴾᶍᶐ

ᵒᶣᵫᵒᴾᶆᶍᶊᶃᶑᴾᶒᵿᶎᶎᶃᶂ

ᵗᵒᶠᵎᵌᵑ

ᵓᵎᶠᵎᵌᵑ

ᵑᶣ᷑ᵔᴾᶆᶍᶊᶃᶑᴾᶍᶐ

ᵑᶣᵫᵓᴾᶆᶍᶊᶃᶑᴾᶒᵿᶎᶎᶃᶂ

Содержание MS65F

Страница 1: ...I N S T R U C T I O N M A N U A L 653 0031 1 Nishi shiriike cho Nagata ku Kobe Japan TEL 078 631 6000 FAX 078 631 6020 READ THE INSTRUCTION MANUAL RoHS Compliant...

Страница 2: ...Caution of piping 6 7 Installation position 6 SETTING OF PRESSURE 1 Switch contact con guration 7 2 Setting of upper limit lower limit 7 3 Reset time 8 ABOUT BUILT IN MICRO SWITCH 1 Material of conta...

Страница 3: ...instrument The instrument is measurable for air and non corrosive gas only The machine is exclusive use of dry air 90 RH or less Using measuring the water or oil it may be damaged and causes the accid...

Страница 4: ...ce pressures Materials of pressure receiving element Pa kPa 60D 10 60 0 01 0 06 2 0 Pa 15 0 Pa Polyester lm 120D 20 120 0 02 0 12 4 0 Pa 20 0 Pa 300D 50 300 0 05 0 3 8 0 Pa 40 0 Pa 600D 100 600 0 1 0...

Страница 5: ...de 10 10 to 50 Hz Acceleration 39 m s2 each two hours on triaxial directions 100 m s2 each six times on triaxial direction Between each terminal and case 20 M or more 500 V DC megger Between each term...

Страница 6: ...trical load type The general electrical load type is decreased contact reliability refer to p 8 The withstanding pressure of the pressure receiving element means The max pressure under which the diaph...

Страница 7: ...nt of negative pressure Connect the tube to the low pressure side piping connector blue or L The high pressure port red or H should be opened to atmosphere but do not remove the piping connector c Mea...

Страница 8: ...it once in a while After the cleaning of the tank check that the air tightness is fully kept c Measurement of high temperature gases In the pressure measurement of high temperature gas use the pressur...

Страница 9: ...pressure the other is called lower limit setting type type L which is adjusted on reset pressure Be careful about the difference between the upper and lower limit setting switched and also understand...

Страница 10: ...contact for low electrical load cross point contact Magni ed drowing of contact for general load small rivet contact point 2 Contact material and applicable mecanism for low voltage and low current c...

Страница 11: ...ive force of inductive load by diode and avoid to apply high voltage to inbetween the contacts This method makes the return time of inductive load slower Choose the diode rated current is more than lo...

Страница 12: ...acid and it may also cause electrical contact failure or malfunction of switches b Silicone gas If the gas to be measured contains silicon produced from silicon contained in oil grease filling agent...

Страница 13: ...ain to x Replacement of air lter In case of using model with air lter MS65F depending on amount of work conduct disassembly and clean out once in 2 years periodically and replace lters and packings wi...

Страница 14: ...rument life For vinyl or plastic tube For metal tube Product code FG VT6 S Product code FG MT6 S T joint For vinyl or plastic tube Product code TVT6 4 6 For branching different I D 6 and 4 Product cod...

Страница 15: ...og speci cations or manual Handling or usage of the product other than as described in our product catalog speci cations or manual 2 Breakdown due to a reason other than a fault within our product 3 A...

Отзывы: