10

VL rotary loose connector type

VK rotary lock connector type

The adaptor of level difference

connector for rotary type

Terminal cover set

Dial cover set

MTW straight connector type (double ring joint)

MK rotary lock connector type

ML rotary loose connector type

MT straight connector type

Filter set

VT straight connector type

Product code KGA65VT

Product code KGA65VRL

Product code KGA65VRK

Product code KGA65ADPA

Product code KGA65MT

Product code KGA65MRL

This connector can be rotated freely

and fi xed at any position.

This connector can be rotated freely

and fi xed at any position.

Product code TCA-65

Product code KGA65MTW-S

Product code AFS65

Two sets of fi lter, Two sets of packing

Product code TCLAMPA-65

This cover avoids trouble that 

someone set dial carelessly.

For stainless tube made from stainless steel

This connector can be rotated freely 

after piping.

4. About measured gas and contact failure

a) Corrosive gas

If  the  gas  to  be  measured  contains  corrosive  gases  (nitric  acid,  hydrogen  sulfide,  sulfurous  acid, 
ammonia,  chlorine,  and  so  on),  they  may  cause  electrical  contact  failure  or  corrosion  of  internal 
mechanism,  which  leads  to  malfunction  of  the  switch.  Do  not  use  the  switch  for  the  gases  containing 
high humid air because in such gases, the arc generated by opening/ closing the contact produces nitric 
acid, and it may also cause electrical contact failure or malfunction of switches.

b) Silicone gas

If the gas to be measured contains silicon produced from silicon (contained in oil, grease, filling agent, 
and  so  on),  the  gas  produced  by  arc,  generates  by  opening/  closing  the  contact,  accumulates  on  the 
contact  surface  and  causes  contact  failure.  Take  corrective  measures  such  as  the  removal  of  the  gas 
source or arc suppression.

c) Dust and organic gas

The micro switch used in a Manostar switch is installed in the positive pressure measurement chamber. 
The  gas  to  be  measured  can  easily  flows  into  the  chamber,  thus,  the  composition  of  the  gas  largely 
affects the formation of the film. In addition, the dust contained in the gas to be measured can adhere to 
the contact surface and be changed into carbide caused the contact failure by the arc generated when 
the contact is opened or closed. Therefore, pay attention to the measurement environment as well.
(Even with gold alloy contact, be careful about the dust.)

!

Caution

As  the  opening/  closing  frequency  of  the  contact  increases,  wear  dust  from  the  contact 
increases. This wear dust accumulates between the contacts to increase the contact resistance 
and causes the malfunction in the load circuit.
In  particular,  the  surrounding  where  there  exists  continuous  vibration  and  impact  will  be  most 
likely to cause contact failure due to worn powder.

Ⅵ. ACCESSORIES

1. Accessory for MS65 (for MS65, MS65F and MS65R)

This connector can be rotated freely 

after piping.

Product code KGA65MRK

Содержание MS65F

Страница 1: ...I N S T R U C T I O N M A N U A L 653 0031 1 Nishi shiriike cho Nagata ku Kobe Japan TEL 078 631 6000 FAX 078 631 6020 READ THE INSTRUCTION MANUAL RoHS Compliant...

Страница 2: ...Caution of piping 6 7 Installation position 6 SETTING OF PRESSURE 1 Switch contact con guration 7 2 Setting of upper limit lower limit 7 3 Reset time 8 ABOUT BUILT IN MICRO SWITCH 1 Material of conta...

Страница 3: ...instrument The instrument is measurable for air and non corrosive gas only The machine is exclusive use of dry air 90 RH or less Using measuring the water or oil it may be damaged and causes the accid...

Страница 4: ...ce pressures Materials of pressure receiving element Pa kPa 60D 10 60 0 01 0 06 2 0 Pa 15 0 Pa Polyester lm 120D 20 120 0 02 0 12 4 0 Pa 20 0 Pa 300D 50 300 0 05 0 3 8 0 Pa 40 0 Pa 600D 100 600 0 1 0...

Страница 5: ...de 10 10 to 50 Hz Acceleration 39 m s2 each two hours on triaxial directions 100 m s2 each six times on triaxial direction Between each terminal and case 20 M or more 500 V DC megger Between each term...

Страница 6: ...trical load type The general electrical load type is decreased contact reliability refer to p 8 The withstanding pressure of the pressure receiving element means The max pressure under which the diaph...

Страница 7: ...nt of negative pressure Connect the tube to the low pressure side piping connector blue or L The high pressure port red or H should be opened to atmosphere but do not remove the piping connector c Mea...

Страница 8: ...it once in a while After the cleaning of the tank check that the air tightness is fully kept c Measurement of high temperature gases In the pressure measurement of high temperature gas use the pressur...

Страница 9: ...pressure the other is called lower limit setting type type L which is adjusted on reset pressure Be careful about the difference between the upper and lower limit setting switched and also understand...

Страница 10: ...contact for low electrical load cross point contact Magni ed drowing of contact for general load small rivet contact point 2 Contact material and applicable mecanism for low voltage and low current c...

Страница 11: ...ive force of inductive load by diode and avoid to apply high voltage to inbetween the contacts This method makes the return time of inductive load slower Choose the diode rated current is more than lo...

Страница 12: ...acid and it may also cause electrical contact failure or malfunction of switches b Silicone gas If the gas to be measured contains silicon produced from silicon contained in oil grease filling agent...

Страница 13: ...ain to x Replacement of air lter In case of using model with air lter MS65F depending on amount of work conduct disassembly and clean out once in 2 years periodically and replace lters and packings wi...

Страница 14: ...rument life For vinyl or plastic tube For metal tube Product code FG VT6 S Product code FG MT6 S T joint For vinyl or plastic tube Product code TVT6 4 6 For branching different I D 6 and 4 Product cod...

Страница 15: ...og speci cations or manual Handling or usage of the product other than as described in our product catalog speci cations or manual 2 Breakdown due to a reason other than a fault within our product 3 A...

Отзывы: