2. Line part accessories

Pulsating protector

In  case  of  strong  turbulent  flow  of  medium  air  that 
causes  abnormal  movement  of  pointer  and  output  of 
transmitter,  installing  a  pulsation  protector  applicable 
pressure  range  one  each  on  H  side  and  L  side  on 
the  piping  way  between  pressure  sensor  and  the 
instrument.

Corrosive gas absorber

In  case  of  measurement  of  gas  which  corrodes  the 
material of the instrument, installing that corrosive gas 
absorber one each on H side and L side each on piping 
way between pressure detector prolong instrument life.

For vinyl or plastic tube

For metal tube

Product code FG-VT6-S

Product code FG-MT6-S

T joint

For vinyl or plastic tube

Product code TVT6-4-6 For branching different I.D. 6 and 4

Product code TVT6-6-6 For branching the same I.D. 6 and 6

Product code

Applicable range (max. value)

For vinyl or plastic tube For metal tube

Pa, kPa

RS-VT6-02

RS-MT6-02

200 Pa or less

RS-VT6-03

RS-MT6-03

300, 500, 1000 Pa

RS-VT6-04

RS-MT6-04

2, 3, 5, 10 kPa

RS-VT6-06

RS-MT6-06

20 kPa or more

Outline drawing for pulsating protector

For vinyl or plastic tube

For metal tube

ᵒᵗ

᷑ᵔᶠᵎᵌᵏ

᷑ᵔᶠᵎᵌᵏ

ᵦᶃᶖᵌᵏᵐ

ᵦᶃᶖᵌᵏᵐ

᷑ᵕ

᷑ᵕ

ᵕᵓ

Outline drawing for corrosive gas absorber

For vinyl or plastic tube

For metal tube

ᵥᶐᵿᶌᶓᶊᵿᶐᴾᵿᶁᶒᶇᶔᵿᶒᶃᶂᴾᶁᵿᶐᶀᶍᶌ

ᵏᵓᵎ

᷑ᵐᵕ

᷑ᵕ

᷑ᵕ

ᵦᶃᶖᵌᵏᵗ

ᵦᶃᶖᵌᵏᵐ

᷑ᵔᶠᵎᵌᵏ

᷑ᵔᶠᵎᵌᵏ

ᵏᵑᵖ

᷑ᵐᵕ

Outline drawing for T joint

For vinyl or plastic tube

Product code TVT6-6-6

Product code TVT6-4-6

ᵑᵗ

ᵏᵖᵌᵓ

ᵑᶣ᷑ᵕ

ᵑᵗ

ᵏᵖᵌᵓ

ᵐᶣ᷑ᵕ

᷑ᵓᵌᵓ

Содержание MS65F

Страница 1: ...I N S T R U C T I O N M A N U A L 653 0031 1 Nishi shiriike cho Nagata ku Kobe Japan TEL 078 631 6000 FAX 078 631 6020 READ THE INSTRUCTION MANUAL RoHS Compliant...

Страница 2: ...Caution of piping 6 7 Installation position 6 SETTING OF PRESSURE 1 Switch contact con guration 7 2 Setting of upper limit lower limit 7 3 Reset time 8 ABOUT BUILT IN MICRO SWITCH 1 Material of conta...

Страница 3: ...instrument The instrument is measurable for air and non corrosive gas only The machine is exclusive use of dry air 90 RH or less Using measuring the water or oil it may be damaged and causes the accid...

Страница 4: ...ce pressures Materials of pressure receiving element Pa kPa 60D 10 60 0 01 0 06 2 0 Pa 15 0 Pa Polyester lm 120D 20 120 0 02 0 12 4 0 Pa 20 0 Pa 300D 50 300 0 05 0 3 8 0 Pa 40 0 Pa 600D 100 600 0 1 0...

Страница 5: ...de 10 10 to 50 Hz Acceleration 39 m s2 each two hours on triaxial directions 100 m s2 each six times on triaxial direction Between each terminal and case 20 M or more 500 V DC megger Between each term...

Страница 6: ...trical load type The general electrical load type is decreased contact reliability refer to p 8 The withstanding pressure of the pressure receiving element means The max pressure under which the diaph...

Страница 7: ...nt of negative pressure Connect the tube to the low pressure side piping connector blue or L The high pressure port red or H should be opened to atmosphere but do not remove the piping connector c Mea...

Страница 8: ...it once in a while After the cleaning of the tank check that the air tightness is fully kept c Measurement of high temperature gases In the pressure measurement of high temperature gas use the pressur...

Страница 9: ...pressure the other is called lower limit setting type type L which is adjusted on reset pressure Be careful about the difference between the upper and lower limit setting switched and also understand...

Страница 10: ...contact for low electrical load cross point contact Magni ed drowing of contact for general load small rivet contact point 2 Contact material and applicable mecanism for low voltage and low current c...

Страница 11: ...ive force of inductive load by diode and avoid to apply high voltage to inbetween the contacts This method makes the return time of inductive load slower Choose the diode rated current is more than lo...

Страница 12: ...acid and it may also cause electrical contact failure or malfunction of switches b Silicone gas If the gas to be measured contains silicon produced from silicon contained in oil grease filling agent...

Страница 13: ...ain to x Replacement of air lter In case of using model with air lter MS65F depending on amount of work conduct disassembly and clean out once in 2 years periodically and replace lters and packings wi...

Страница 14: ...rument life For vinyl or plastic tube For metal tube Product code FG VT6 S Product code FG MT6 S T joint For vinyl or plastic tube Product code TVT6 4 6 For branching different I D 6 and 4 Product cod...

Страница 15: ...og speci cations or manual Handling or usage of the product other than as described in our product catalog speci cations or manual 2 Breakdown due to a reason other than a fault within our product 3 A...

Отзывы: