Ruijie XS-S1920 Series Switches

 

Hardware Installation and Reference Guide V1.1

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание XS-S1920 Series

Страница 1: ...Ruijie XS S1920 Series Switches Hardware Installation and Reference Guide V1 1 ...

Страница 2: ... or by any means without the prior written consent of Ruijie Networks is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any notice Please obtain the latest information through the Ruijie Networks website Ruijie Networks endeavors to ensure content accuracy and will not shoulder any responsibility for losses and damages cau...

Страница 3: ... Technical Support Website https ruijienetworks com support Case Portal https caseportal ruijienetworks com Community https community ruijienetworks com Technical Support Email service_rj ruijienetworks com Skype service_rj ruijienetworks com Related Documents Documents Description Configuration Guide Describes network protocols and related mechanisms that supported by the product with configurati...

Страница 4: ...le with 100Base FX 100M optical modules should be used with 100Base FX 1000Base T is compatible with 100Base TX and 10Base T in the downlink direction 1 1 XS S1920 9GT1SFP P E Technical Specifications Model XS S1920 9GT1SFP P E CPU Built in CPU single core processor 500MHz Flash Memory 32MB SDRAM DDRIII 256MB Optical Module For details see Appendix B The supported module type may change at any tim...

Страница 5: ...ards GB4943 2011 Earth Leakage Current 1 5mA Dimensions W x D x H 300 mm x 220 mm x 43 6 mm Weight 2 kg with package The XS S1920 9GT1SFP P E switch is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures The label indicates that you should not touch the device when it operates in environments of more...

Страница 6: ...2 Hole for anti theft lock 3 Power cord retention clip 4 AC power port Heat Dissipation The XS S1920 9GT1SFP P E adopts natural heat dissipation thereby ensuring normal function of the device in the specified environment 10 cm distance space should be reserved at both sides and the back plane of the cabinet to allow air circulation It is recommended to clean the device once every 3 months to avoid...

Страница 7: ...ransmitting traffic at 10 100 1000 Mbps Off The port is not connected Solid green The port is connected at 100 1000 Mbps 1000Mbps SFP port status LED 10F Blinking green The port is receiving or transmitting traffic at 100 1000 Mbps 1 2 XS S1920 24T2GT2SFP LP E Technical Specifications Model XS S1920 24T2GT2SFP LP E CPU Built in CPU single core processor 500MHz Flash Memory 32MB SDRAM DDRIII 256MB ...

Страница 8: ...midity 10 to 90 RH Storage Humidity 5 to 95 RH Fan Speed adjustment Temperature Warning Not supported Accessing Optical Module Information Not supported EMC Standards GB9254 2008 Security Standards GB4943 2011 Earth Leakage Current 1 5mA Dimensions W x D x H 440 mm x 292 mm x 43 6 mm Weight 4 2 kg with package The XS S1920 24T2GT2SFP LP E switch is a class A product In a domestic environment this ...

Страница 9: ...ack Panel Figure 1 6 Back Panel of XS S1920 24T2GT2SFP LP E Note 1 Grounding pole 2 Vent 3 Power cord retention clip 4 AC power port Heat Dissipation The XS S1920 24T2GT2SFP LP E adopts turbine fans for heat dissipation thereby ensuring normal function of the device in the specified environment 10 cm distance space should be reserved at both sides and the back plane of the cabinet to allow air cir...

Страница 10: ...es errors System status LED Status Solid green The switch is operational Off Indicates the switching state PoE status LED PoE Solid green Indicates the PoE state Off PoE is not enabled Solid green PoE is enabled The port is operational RJ45 port PoE status LED 1 24 Blinking green Indicates PoE overload Off The port is not connected 100Mbps RJ 45 port status LED 1 24 Solid green The port is connect...

Страница 11: ... E Technical Specifications Model XS S1920 24T2GT2SFP P E CPU Built in CPU single core processor 500MHz Flash Memory 32MB SDRAM DDRIII 256MB Optical Module For details see Appendix B The supported module type may change at any time Consult us for the latest information SFP Port Supports 1000Base X and 100Base FX modules Power Supply AC input Rated voltage range 100V to 240V Maximum voltage range 9...

Страница 12: ...t 1 5mA Dimensions W x D x H 440 mm x 292 mm x 43 6 mm Weight 4 2 kg with package The XS S1920 24T2GT2SFP P E switch is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Product Appearance On the front panel the XS S1920 24T2GT2SFP P E Ethernet switch provides twenty four 10 100Baes T Ethernet port...

Страница 13: ... of XS S1920 24T2GT2SFP P E Note 1 Grounding pole 2 Vent 3 Power cord retention clip 4 AC power port Heat Dissipation The XS S1920 24T2GT2SFP P E adopts turbine fans for heat dissipation thereby ensuring normal function of the device in the specified environment 10 cm distance space should be reserved at both sides and the back plane of the cabinet to allow air circulation It is recommended to cle...

Страница 14: ...J45 port PoE status LED 1 24 Blinking green Indicates PoE overload Off The port is not connected Solid green The port is connected at 10 100 Mbps 100Mbps RJ 45 port status LED 1 24 Blinking green The port is receiving or transmitting traffic at 10 100 Mbps Off The port is not connected Solid green The port is connected at 100 1000 Mbps 1000Mbps SFP port status LED 27 28F Blinking green The port is...

Страница 15: ...cord requirement 10A EEE Supported PoE Supports PoE and PoE Ports 1 24 are PoE PoE capable with the maximum power output of 30W per port Ports 25 and 26 do not support PoE or PoE The overall maximum output power of PoE PoE is 185W PoE Mode Mode A data pairs 1 2 and 3 6 Power Consumption Less than 25W with no PoE load Less than 226W with PoE full load Operating Temperature 5 to 55 23 F to 131 F Sto...

Страница 16: ...y six 10 100 1000Baes T Ethernet ports two 1000M SFP ports and one Console port On the back panel it provides AC power ports Figure 1 12 Appearance of XS S1920 26GT2SFP LP E Front Panel Figure 1 13 Front Panel of XS S1920 26GT2SFP LP E Note 1 System status LED 2 PoE status LED 3 Console port 4 PoE Mode Switch Over Button 5 10 100 1000Base T auto sensing Ethernet port 6 Copper port status LED 7 Cop...

Страница 17: ...ack plane of the cabinet to allow air circulation It is recommended to clean the device once every 3 months to avoid dust from blocking vents Figure 1 15 shows the flow scheme of heat dissipation Figure 1 15 Flow Scheme of Heat Dissipation LEDs LED Panel Identification State Meaning Off The switch is not receiving power Blinking green The system is being initialized Continuous blinking indicates e...

Страница 18: ...ing green The port is receiving or transmitting traffic at 100 1000 Mbps 1 5 XS S1920 26GT2SFP P E Technical Specifications Model XS S1920 26GT2SFP P E CPU Built in CPU single core processor 500MHz Flash Memory 32MB SDRAM DDRIII 256MB Optical Module For details see Appendix B The supported module type may change at any time Consult us for the latest information SFP Port Supports 1000Base X and 100...

Страница 19: ...ported EMC Standards GB9254 2008 Security Standards GB4943 2011 Earth Leakage Current 1 5mA Dimensions W x D x H 440 mm x 292 mm x 43 6 mm Weight 4 2 kg with package The XS S1920 26GT2SFP P E switch is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Product Appearance On the front panel the XS S1...

Страница 20: ...anel of XS S1920 26GT2SFP P E Note 1 Grounding pole 2 Vent 3 Power cord retention clip 4 AC power port Heat Dissipation The XS S1920 26GT2SFP P E adopts turbine fans for heat dissipation thereby ensuring normal function of the device in the specified environment 10 cm distance space should be reserved at both sides and the back plane of the cabinet to allow air circulation It is recommended to cle...

Страница 21: ...en The switch is operational Off Indicates the switching state PoE status LED PoE Solid green Indicates the PoE state Off PoE is not enabled Solid green PoE is enabled The port is operational RJ45 port PoE status LED 1 24 Blinking green Indicates PoE overload Off The port is not connected Solid green The port is connected at 10 100 1000 Mbps 1000Mbps RJ 45 port status LED 1 26 Blinking green The p...

Страница 22: ... supplies and remove the power sockets and cables before installing or uninstalling the device 2 1 2 Movement Do not frequently move the device When moving the device note the balance and avoid hurting legs and feet or straining the back Before moving the device turn off all power supplies and dismantle all power modules 2 1 3 Electricity Observe local regulations and specifications when performin...

Страница 23: ...all be 50 of the leakage action current Take a leakage protector with 30mA rated leakage action current as an example The rated leakage non action current shall be 15mA When the leakage current is below 15mA the protector shall not act Otherwise misoperation may easily occur due to high sensitivity and thus the leakage protector trips devices are powered off and services are interrupted To guarant...

Страница 24: ... parts may get rusted In an environment with low relative humidity however the insulating strip may dry and shrink Static electricity may occur easily and endanger the circuit on the equipment In an environment with high temperature the equipment is subject to even greater harm as its performance may degrade significantly and various hardware faults may occur Therefore the ambient temperature and ...

Страница 25: ... The single phase three wire socket with protecting grounding must be used as the socket for the power supply to enable the device s upper filter circuit to effective filter the power interface The switch should be far from high power radio transmitting stations radar stations and high frequency and large current devices Electromagnetic shielding methods should be applied when necessary such as us...

Страница 26: ...the grounding system which usually shares the power reference ground and yellow green safety cable ground The lightning discharge ground is for the facility only irrelevant to the equipment EMC Grounding The grounding required for EMC design includes shielding ground filter ground noise and interference suppression and level reference All the above constitute the comprehensive grounding requiremen...

Страница 27: ...may affect any signal path in the equipment and is difficult to shield For the AC power supply system TN single phase three core power socket with protective earthing conductors PE should be adopted to effectively filter out interference from the power grid through the filtering circuit The grounding device of the switch must not be used as the grounding device of the electrical equipment or anti ...

Страница 28: ...before Installation Before installation please confirm the following points Whether ventilation requirements are met for the switch Whether the requirements of temperature and humidity are met for the switch Whether power cables are already laid out and whether the requirements of electrical current are met Whether related network adaption lines are already laid out 3 3 Installing the XS S1920 Pre...

Страница 29: ...ch pad radar launch pad and high frequency large current devices If necessary electromagnetic shielding should be adopted For example use interface cables to shield cables 100 meter network cables should be laid inside the equipment room and outdoor cabling of such cables is prohibited If outdoor cabling is necessary take relevant measures for lightning protection 3 3 1 Mounting the Switch to a St...

Страница 30: ...to Install S1920 9GT1SFP P E Figure 3 4 Aligning Holes to Install S1920 24T2GT2SFP LP E S1920 26GT2SFP LP E Use the supplied M6 screws and cage nuts to securely attach the mounting brackets to the rack as shown in Figure 3 5 and Figure 3 6 Figure 3 5 Attaching the Brackets to the Rack to Install S1920 9GT1SFP P E Figure 3 6 Attaching the Brackets to the Rack to Install S1920 24T2GT2SFP LP E S1920 ...

Страница 31: ...switch with the supplied screws as shown in Figure 3 7 and Figure 3 8 Figure 3 7 Attaching the Mounting Brackets to S1920 9GT1SFP P E for Wall Mounting Figure 3 8 Attaching the Mounting Brackets to S1920 24T2GT2SFP LP E S1920 26GT2SFP LP E for Wall Mounting Use the expansion screws to securely attach the mounting brackets on the wall as shown in Figure 3 9 and Figure 3 10 Figure 3 9 Attaching S192...

Страница 32: ... Wall SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON COMBUSTIBLE SURFACE ONLY 3 3 3 Mounting the Switch on a Table Attach the four rubber feet to the recessed areas on the bottom of the switch as shown in Figure 3 11 Figure 3 11 Attaching the Rubber Feet to the Recessed Areas Place the switch on the table as shown in Figure 3 12 Figure 3 12 Mounting the Switch on the Table ...

Страница 33: ...id any personal injury or damage to the component due to connection errors Check that the ground line is connected Check that the cables and power input cables are correctly connected Check that all interface cables are laid out inside the equipment room In the case of external cabling check that the lightning resistance socket or network interface lightning protector is connected Check that suffi...

Страница 34: ... with DB 9 jack to the serial port of the PC Step 2 Connect the end of the console cable with RJ45 to the console port of the switch Setting HeperTerminal Parameters Step 1 Start the PC and run the terminal simulation program on the PC such as Terminal on Windows 3 1 or HyperTerminal on Windows 95 98 NT 2000 XP Step 2 Set terminal parameters The parameters are as follows baud rate 9600 data bit 8 ...

Страница 35: ...as shown in figure 4 3 is displayed Choose the serial port used currently in the column use when connecting Figure 4 3 4 After choosing the serial port click OK to display the serial port parameter setting interface set the baud rate to 9600 data bit to 8 parity check to none stop bit to 1 and flow control to none Figure 4 4 ...

Страница 36: ...console port of the switch The HyperTerminal is started and the parameter settings are correct 4 2 2 Checking after Program Startup Recommended After power on you are recommended to perform the following checks to ensure the normal operation of follow up configurations Check whether information is displayed on the terminal interface Check whether the status of the switch indicator is normal Check ...

Страница 37: ...ocket at the equipment room is normal and whether the power cable of the switch is in good contact The serial port console has no output or outputs illegible characters The serial port connected to the switch does not match that opened by the configuration software The serial port is not configured correctly Change the serial port opened by the configuration software to be the one connected to the...

Страница 38: ...ected The Rx and Tx ends are connected reversely The interconnected optical module type does not match The fiber type is not correct The length of the optical fiber exceeds that rated of the optical module Switch the Rx and Tx ends of the optical fiber Replace the optical module with one of the matched type Replace the optical fiber with one of the appropriate type Replace the optical fiber with o...

Страница 39: ...rt uses four pairs of wires for transmission all of which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Four Twisted Pairs of the 1000BASE T In addition to the above cables the 100BASE TX 10BASE T can also use 100 ohm Category 3 4 5 cables for 10 Mbps and 100 ohm Category 5 cables for 100 Mbps both of which can be up to 100 m Figure ...

Страница 40: ...nd SPF Module Optical Fiber Connection For the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection schematic diagram is shown in Figure A 4 Figure A 4 Optical Fiber Connections ...

Страница 41: ...P LH15 SM1310 1310 SMF Yes 15 8 28 8 FE SFP LH20 SM1310 SGMII 1310 SMF No 15 8 28 8 FE SFP LX20 SM1310 BIDI 1310TX 15 50RX SMF Yes 15 7 28 8 FE SFP LX20 SM1550 BIDI 1550TX 13 10RX SMF Yes 15 7 28 8 FE SFP LH40 SM1310 BIDI 1310TX 15 50RX SMF Yes 7 2 32 8 FE SFP LH40 SM1550 BIDI 1550TX 13 10RX SMF Yes 7 2 32 8 FE eSFP LH15 SM1310 1310 SMF Yes 15 8 28 8 Mini GBIC SX 850 MMF No 9 5 3 17 0 Mini GBIC LX...

Страница 42: ... LX LC SMF 9 125 10km 62 5 125 275m GE eSFP SX MM850 LC MMF 50 125 550m GE eSFP LX SM1310 LC SMF 9 125 10km GE SFP LX SM1310 LC SMF 9 125 10km Mini GBIC LH40 LC SMF 9 125 40km GE SFP SX SM1310 BIDI LC MMF 50 125 500m GE SFP SX SM1550 BIDI LC MMF 50 125 500m GE SFP LX20 SM1310 BIDI LC SMF 9 125 20km GE SFP LX20 SM1550 BIDI LC SMF 9 125 20km GE SFP LH40 SM1310 BIDI LC SMF 9 125 40km GE SFP LH40 SM15...

Страница 43: ...n please use dust caps when the modules are not connected with fibers No extra cables are needed when SFP cables are used Inserting the two ends of a SFP cable into corresponding ports facilitates inter communication between the two ports Table B 8 Specifications of SFP BIDI Optical Module Pairs Rate Distance Module Pairs 1000M 500m GE SFP SX SM1310 BIDI GE SFP SX SM1550 BIDI 1000M 20km GE SFP LX2...

Страница 44: ...cautions for installation Make sure that the PE terminal of the power arrester has been well grounded After connecting the switch AC power plug to the socket of the power arrester lightning protection cable row lightning protection function implements if the RUN LED is Green and the ALARM LED is OFF If the ALARM LED on the power arrester is Red you shall check what the reason is poor grounding con...

Страница 45: ... the grounding line for the arrester is in good contact with the switch grounding terminal and the framework 4 According to the description on the Ethernet Port Arrester Hardware Installation Guide connect the arrester using the adapter cable note that the external network cable is connected to the end of IN while the adapter cable connected to the switch is connected to the end of OUT and observe...

Страница 46: ...UT end Poor arrester grounding The length of the grounding line should be as short as possible to ensure that it is in good contact with the switch grounding terminal Use the multimeter to confirm the contact condition after the grounding Incomplete arrester installation If there is more than one port connected to the peer device on the switch it needs to install the arresters on all connection po...

Страница 47: ...end or suffer removal insertion should be greater than seven times their respective diameters The bend radius of a common coaxial cable should be greater than seven times its diameter The bend radius of this type of cables that often bend or suffer removal insertion should be greater than 10 times its diameter The bend radius of a high speed cable SFP cable for example should be greater than five ...

Страница 48: ... be smooth without sharp corners The metal hole traversed by cables should have a smooth and fully rounding surface or an insulated lining Proper buckles should be selected to bundle up cables It is forbidden to connect two or more buckles to bundle up cables After bundling up cables with buckles you should cut off the remaining part The cut should be smooth and trim without sharp corners as shown...

Страница 49: ...sioning The power cords cannot be bundled on the guide rails of moving parts The power cables connecting moving parts such as door grounding wires should be reserved with some access after assembled When the moving part reaches the installation position the remaining part should not touch heat sources sharp corners or sharp edges If heat sources cannot be avoided high temperature cables should be ...

Страница 50: ...ling direction should be bundled up into cable bunches with cables in cable bunches clean and straight Binding by using buckles should be performed according to Table D 1 Cable Bunch Diameter mm Binding Space mm 10 80 150 10 30 150 200 30 200 300 No knot is allowed in cabling or bundling For solder less terminal blocks such as air switches of the cold pressing terminal type the metal part of the c...

Страница 51: ...as windstorm and heavy rain as well as away from dust If the dust is unavoidable keep the door and window away from the pollution source The machine room should be away from the residential area Otherwise the machine room should meet the construction standard in terms of noise Make sure the air vent of the machine room is away from the sewage pipe septic tank and sewage treatment tank Keep the mac...