3 - 22
INSP
ADJ
VALVE CLEARANCE INSPECTION AND ADJUSTMENT
●
Remove the decompression cable
1
,
guide
2
, bolt
3
and decompression shaft
4
.
●
Remove the valve lifters
5
and the pads
6
.
NOTE:
●
Place a rag in the timing chain space to
prevent pads from falling into the crank-
case.
●
Identity each valve lifter and pad position
very carefully so that they can be rein-
stalled in their original place.
●
Select the proper pad using the pad
selecting table.
Pad range
Pad Availability:
25 increments
No. 120
~
No. 240
1.20 mm
~
2.40 mm
Pads are available in
0.05 mm increments
NOTE:
The thickness
a
of each pad is indicated in
hundreths of millimeters on the pad upper
surface.
●
Round off the last digit of the installed pad
number to the nearest increment.
Last digit of pad
number
Rounded value
0 or 2
0
5
(NOT ROUNDED
OFF)
8
10
EXAMPLE:
Installed pad number = 148
Rounded off value = 150
NOTE:
Pads can only be selected in 0.05 mm incre-
ments.