6 - 25
FI
FUEL INJECTION SYSTEM
Fault code No.
46
Symptom Power supply is not normal.
Diagnostic code No. —
—
Order Item/components and probable
cause
Check or maintenance job
Reinstatement
method
1
Connections
• Main wire harness-ECU coupler
• Check the coupler for any pins
that may be pulled out.
• Check the locking condition of
the coupler.
• If there is a malfunction, repair it
and connect the coupler
securely.
Starting the
engine and
operating it at
idle.
2
Faulty battery.
• Replace or charge the battery.
Refer to “CHECKING AND
CHARGING THE BATTERY” in
chapter 3.
3
Malfunction in rectifier/regulator
• Replace if defective.
Refer to “CHARGING SYSTEM”
in chapter 9.
4
Open or short circuit in wire har-
ness.
• Repair or replace if there is an
open or short circuit.
• Between battery lead and main
fuse coupler
(red–red)
• Between main fuse coupler and
ignition fuse
(red–red)
• Between main switch coupler
and ignition fuse
(red/black–red/black)
• Between main switch coupler
and ECU coupler
(brown/red–brown/red)
Fault code No.
50
Symptom Faulty ECU memory. (When this malfunction is detected
in the ECU, the fault code number might not appear on
the meter.)
Diagnostic code No. —
—
Order Item/components and probable
cause
Check or maintenance job
Reinstatement
method
1
Malfunction in ECU.
Replace the ECU.
TIP:
Do not perform this procedure with
the main switch turned to “ON”.
Turning the
main switch to
“ON”.
Содержание YXR70FX
Страница 1: ...SERVICE MANUAL 2008 LIT 11616 21 58 5B4 F8197 10 YXR70FX...
Страница 6: ......
Страница 46: ...2 11 SPEC ENGINE SPECIFICATIONS Cylinder head tightening sequence 6 8 5 7 2 1 4 3...
Страница 495: ......