7-17
-
+
ELEC
EAS00758
3. Starter motor
8
Connect the positive battery terminal
1
and starter motor lead
2
with a jumper
lead
3
.
w
8
8
8
8
8
A wire that is used as a jumper lead must
have at least the same capacity or more
as that of the battery
lead, otherwise
the jumper lead may burn.
8
8
8
8
8
This check is likely to produce sparks,
therefore make sure nothing flammable
is in the vicinity.
8
Does the starter motor turn?
YES
NO
Repair or replace the
starter motor.
EAS00759
4. Starting circuit cut-off relay
8
Disconnect the starting circuit cut-off re-
lay coupler from the wire harness.
8
Connect the pocket tester (
Ω
×
1) and
battery (12 V) to the starting circuit cut-
off relay coupler as shown.
Positive battery terminal
J
J
J
J
J
red/white
1
1
1
1
1
Negative battery terminal
J
J
J
J
J
blue/white
2
2
2
2
2
Positive tester probe
J
J
J
J
J
green/yellow
3
3
3
3
3
Negative tester probe
J
J
J
J
J
sky blue
4
4
4
4
4
8
Does the starting circuit cut-off relay have
continuity between green/yellow
3
and
sky blue
4
?
YES
NO
Replace the starting
circuit cut-off relay.
1
3
4
× 1Ω
2
12V
ELECTRIC STARTING SYSTEM