2-5
SPEC
E
MAINTENANCE SPECIFICATIONS
ELECTRICAL
Item
Unit
Model
XL1200Ltd
BATTERY
Type
Fluid
Capacity
V-Ah (kC)
12 - 19 (68.4)
CDI UNIT
(B/W – B)
Output peak voltage lower
limit
@cranking 1
V
200
@cranking 2
V
180
@2,000 r/min
V
190
@3,500 r/min
V
180
STATOR
Pickup coil
(W/R – B/O)
Output peak voltage
lower limit
@cranking 1
V
5
@cranking 2
V
2.8
@2,000 r/min
V
7.9
@3,500 r/min
V
11
Lighting coil
(G – G)
Output peak voltage
lower limit
@cranking 1
V
9
@cranking 2
V
9
@2,000 r/min
V
14
@3,500 r/min
V
14
Pickup coil resistance
Ω
(color)
445 ~ 545 (W/R – B/O)
Lighting coil resistance
Ω
(color)
0.49 ~ 0.59 (G – G)
Minimum charging current
A @ r/min
9 @ 6,000
IGNITION COIL
Minimum spark gap
mm (in)
10 (0.39)
Primary coil resistance
Ω
(color)
0.26 ~ 0.36 (B/W – Ground)
Secondary coil resistance
k
Ω
(color)
3.5 ~ 4.7 (B/W – Spark plug lead terminal)
Spark plug lead resistance
#1
k
Ω
6.1 ~ 14.3
#2
k
Ω
4.6 ~ 11.1
#3
k
Ω
3.1 ~ 7.7
Cranking 1: unloaded
Cranking 2: loaded
Содержание WaveRunner XL1200Ltd
Страница 1: ...LIT186160198 LIT 18616 01 98 F0D 28197 Z9 11 SERVICE MANUAL WaveRunner XL1200Ltd ...
Страница 87: ...5 8 POWR E MUFFLER ASSEMBLY SERVICE POINT Catalyst inspection 1 Inspect Catalyst Cracks damage Replace ...
Страница 240: ...E 1 2 3 4 5 6 7 8 9 TRBL ANLS CHAPTER 9 TROUBLE ANALYSIS TROUBLE ANALYSIS 9 1 TROUBLE ANALYSIS CHART 9 1 ...
Страница 244: ...YAMAHA MOTOR CO LTD Printed in USA Mar 1999 1 CR XA1200X Printed on recycled paper ...