7-41
E
–
+
ELEC
INDICATION SYSTEM
Overheat warning indicator
1. Check:
●
Overheat 1 warning indicator
Not operating
→
Replace the multi-
function meter.
Checking steps:
●
Supply DC 12 voltage to the white six-
pin connector (+: red, –: black) with a
battery.
●
Connect the gray/black and black ter-
minals with a jumper lead
1
.
●
Connect the green and red terminals
with a jumper lead
2
.
●
Make sure the water temperature
warning indicator blinks
3
and the
“
”
message
4
blinks, the
“WARNING” lamp
5
blinks, and the
buzzer sounds intermittently.
2. Check:
●
Overheat 2 warning indicator
Not operating
→
Replace the multi-
function meter.
Checking steps:
●
Supply DC 12 voltage to the white six-
pin connector (+: red, –: black) with a
battery.
●
Connect the gray/red and black termi-
nals with a jumper lead
1
.
●
Connect the green and red terminals
with a jumper lead
2
.