THERMO UNIT SYSTEM
6-15
EC624000
COUPLERS AND LEADS CONNECTION
INSPECTION
1. Check:
• Couplers and leads connection
Rust/ Dust/ Looseness/Short-circuit
≥
Repair or replace.
EC6A2000
THERMO UNIT INSPECTION
1. Drain the cooling water.
2. Remove:
• Thermo unit
1
3. Immerse the thermo unit with a tester lead
connected in a container containing cooling
(tap) water
1
down to the upper threaded
portion
a
.
2
Water temperature gauge
3
Poket tester
4. Inspect:
• Thermo unit resistance
Measure the resistance while gradually
heating the cooling water.
Out of specification
≥
Replace .
Cooling
Thermo
Tester
water
unit
selector
temperature resistance position
50˚C (122˚F) 9.72~11.4 k
Ω
k
Ω
X
X
1
80˚C (176˚F) 3.41~4.01 k
Ω
NOTE:
Do not allow the thermo unit to contact the test
container bottom.