60H5E11
Troubleshooting
TRBL
SHTG
NOTE:
• To diagnose a mechanical malfunction, use the troubleshooting charts pertaining to the trouble
located in this chapter. Also, when checking and maintaining the outboard motor, see Chapters
4–8, to check the part necessary to carry out safety maintenance.
• Check that all electrical connections are tight and free from corrosion, and that the battery is fully
charged to 12 V.
Power unit
Symptom: Engine does not crank.
• Check the starting system.
• Check the power unit.
Starting system
Yes
No
Yes
No
Yes
No
Check that the gear shift is in the
neutral position.
Is the gear shift
in neutral?
Set it to the neutral position.
Check the neutral switch inside
remote control box for continuity.
Is there
continuity?
Replace the neutral switch.
Check the engine start switch
for continuity.
Is there
continuity?
Replace the engine start switch.
Check the fuse for continuity.
Continued on next page.