Appendix ES2 Series Servo User Manual Lite V1.0
47
P04
22
Position
deviation
clear function
0- Clear position
deviation pulse
when fault occurs
or servo OFF
1- Clear the
position deviation
pulse only when a
fault occurs
2- Cleared by DI
input function
(PERR-CLR)
1
0
Effective
immediate
ly
Settin
g after
motor
stop
P
P04
23
Positioning complete
(COIN) output
0-Output when the
absolute position
deviation value is
smaller than
positioning
completion range
1- Output when the
absolute position
deviation value is
smaller than
positioning
completion range
and the filtered
position command
is 0
2- Output when the
absolute position
deviation value is
smaller than
positioning
completion range
and position
command is 0
1
0
Effective
immediate
ly
Settin
g after
motor
stop
P
P04
24
Positioning
completion range
1P
~
65535P
1P
7P
Effective
immediate
ly
Settin
g after
motor
stop
P
P04
25
Positioning
close
range
1P
~
65535P
1P
65535P
Effective
immediate
ly
Settin
g after
motor
stop
P
P05 group: speed control parameters
Function
code
Name
Setting range
Min.
unit
Default
setting
Effective
time
Type
Mode
P05
00
Main speed command
A source
0-digit
value(P0503)
3-multi-speed
command
4-communication
command given
1
0
Effective
immediately
Settin
g after
motor
stop
S
P05
01
Auxiliary
speed
command B source
0-digit
value(P0503)
3-multi-speed
command
4-communication
command given
1
3
Effective
immediately
Settin
g after
motor
stop
S