Chapter 3: Servo Drive and Motor Connection
Option 3: Use external resistors and PNP type
Resistance R1 select formula
:
R1 recommended values
VCC voltage
24V
12V
5V
3.5 Communication signals
Mini USB communication
Through CN5, communication
operations such as drive status monitoring, test operation, and parameter reading and writing.
Chapter 3: Servo Drive and Motor Connection ES2 Series Servo User Manual Lite V1.0
19
Option 3: Use external resistors and PNP type
:
.
= 10mA
voltage
R1 resistance
R1 power
24V
2.4KΩ
0.5W
12V
1.5KΩ
0.5W
5V
200Ω
0.5W
communication CN5
Through CN5, communication between PC and driver can be established, and implement
operations such as drive status monitoring, test operation, and parameter reading and writing.
ES2 Series Servo User Manual Lite V1.0
between PC and driver can be established, and implement
operations such as drive status monitoring, test operation, and parameter reading and writing.