Appendix ES2 Series Servo User Manual Lite V1.0
40
P00 group: basic control parameters
Function
code
Name
Setting range
Min. unit
Default
setting
Effectiv
e time
Type
Mode
P00
00
Control
mode
selection
0-position mode
1-speed mode
2-torque mode
3-speed / torque mixing
mode
4-position / speed mixing
mode
5-position / torque mixing
mode
6-reserved
7-pulse/speed
mixing
mode
1
0
Effectiv
e
immedia
tely
Settin
g after
motor
stop
PST
P00
01
Direction
of
rotation
0-CCW direction is the
forward direction
(counterclockwise)
1-CW direction is the
forward direction
(clockwise)
1
0
Re-
power
Settin
g after
motor
stop
PST
P00
02
Pulse
output
positive
direction
definition
0-CCW direction is
forward direction
(the corresponding
motor rotation direction
when the pulse output
OA leads the OB)
1- CW direction is
forward direction
(reverse mode, OA lag
OB)
1
0
Re-
power
Settin
g after
motor
stop
PST
P00
03
Self-adjusting
mode
0-invalid
1-standard mode
2-positioning mode
1
0
Effectiv
e
immedia
tely
Settin
g after
motor
stop
PST
P00
04
Rigidity
level
setting
0~31
1
11
Effectiv
e
immedia
tely
Set
when
runnin
g
PST
P00
05
Inertia ratio
0~3000
0.01
1.00
Effectiv
e
immedia
tely
Set
when
runnin
g
PST
P00
07
Maximum
speed of the
system
0~10000rpm
1rpm
6000rp
m
Effectiv
e
immedia
tely
Settin
g after
motor
stop
PST
P00
08
System
maximum
torque
0~500 (times to the rated
torque of motor)
0.01
3.00
Effectiv
e
immedia
tely
Settin
g after
motor
stop
PST
P00
10
Servo OFF stop
mode
0-Free running stop, keep
free
1-zero speed stop, keep
free
1
0
Effectiv
e
immedia
tely
Settin
g after
motor
stop
PST
P00
11
Reserved
parameter
0
~
65535
1
0
N/A
Reser
ved
param
eter
PST
P00
12
Fault No.2 stop
mode selection
0-Free running stop, keep
free
1-zero speed stop, keep
free
1
0
Effectiv
e
immedia
tely
Settin
g after
motor
stop
PST