Appendix ES2 Series Servo User Manual Lite V1.0
70
Input signal function description
Code
Name
Function Name
Description
Status
FunIN.11
ZERO_CLAMP
Zero postion fixed
function
enable
signal
Valid -enable zero postion fixed function,
Invalid-disable zero postion fixed function
Assign
FunIN.12
INHIBIT
Pulse inhibit
Valid - disable command pulse input
Invalid - allow command pulse input
Assign
FunIN.13
P_OT
Forward
overtravel
When the mechanical movement
exceeds the movable range limit
switch, the overtravel protection
function is activated.
Active-forward overtravel, forward
run disabled
Invalid - normal range, forward run
enabled
Assign
FunIN.14
N_OT
Backward
overtravel
When the mechanical movement exceeds
the movable range limit switch, the
overtravel protection function is activated.
Active-backward overtravel, backward
run disabled
Invalid - normal range, backward run
enabled
Assign
FunIN.15
Reserved
Assign
FunIN.16
Reserved
Assign
FunIN.17
P_JOG
Forward JOG
Valid - input according to given
command
Invalid - stop input run command
Assign
FunIN.18
N_JOG
Backward JOG
Valid - input reversely according to given
command
Invalid - stop input run command
Assign
FunIN.23
GEAR_SWITCH
Electronic
gear
selection
Invalid - electronic gear ratio 1
Valid - electronic gear ratio 2
Assign
FunIN.24
POS_DIR
Position command
reversal
Invalid - no reversal; effective - reversal
Assign
FunIN.25
SPD_DIR
Speed command
reversal
Invalid - no reversal; effective - reversal
Assign
FunIN.26
TOG_DIR
Torque command
reversal
Invalid - no reversal; effective - reversal
Assign
FunIN.29
PSEC_EN
Internal
multi-
segment position
enable signal
Edge effective:
Invalid - ignore internal multi-segment
command;
Valid - start internal multi-segment
Assign
FunIN.30
XINT_FINISH
External
confirmation
signal of
interrupt fixed
length
completion
Edge valid
Invalid - no response; valid - trigger
interrupt
Assign
FunIN.31
XINT_DISABLE
Disable interrupt
fixed length
Level effective
Invalid - no response; valid - trigger
interrupt
Assign
FunIN.32
HOME_SWITCH
Home
switch
signal
Mechanical home switch
Assign
FunIN.33
HOME_START
Homing
enable
signal
Homing start
Assign
FunIN.34
ESTOP
Emergency stop
Assign
FunIN.35
POS_RUN
Position
loop
constant
speed
running
Assign