Appendix ES2 Series Servo User Manual Lite V1.0
67
Function
code
Name
Setting range
Min.
unit
Default
setting
Effective
time
Type
Mode
P16
11
Low-speed for
searching home
switch signal
10 rpm -1000 rpm
1
rpm
10 rpm
Effective
immediate
ly
Settin
g after
motor
stop
P
P16
12
Limit the accel.
/ decel. time for
searching home
0-65535ms
1ms
1000ms
Effective
immediate
ly
Settin
g after
motor
stop
P
P16
13
Limit time for
finding home
0-65535ms
1ms
10000m
s
Effective
immediate
ly
Settin
g after
motor
stop
P
P16
14
Mechanical
home offset (32
bits)
-1073741824
~
1073741824(command unit)
1Un
it
0 Unit
Effective
immediate
ly
Settin
g after
motor
stop
P
P18 group: display parameters
Function
code
Name
Setting range
Min.
unit
Default
setting
Effective
time
Type
Mode
P18
00
Servo status
rdy
、
run
、
Err.00~99
(
error
)
,AL.00~10(
warning
)
1
-
N/A
Displa
y
param
eter
PST
P18
01
Motor
speed
feedback (32 bit)
-9000rpm~9000rpm
1rpm
-
N/A
Displa
y
param
eter
PST
P18
03
Speed command
-9000rpm~9000rpm
1rpm
-
N/A
Displa
y
param
eter
PST
P18
04
Internal
torque
command (based on
rated torque)
-500.0%~500.0%
0.1%
-
N/A
Displa
y
param
eter
PST
P18
05
Phase current RMS
0.00A~655.35A
0.01A
-
N/A
Displa
y
param
eter
PST
P18
06
Bus voltage value
0V~1000V
0.1V
-
N/A
Displa
y
param
eter
PST
P18
07
Absolute
position
counter (32 bit)
-1073741824
~
1073741824(comman
d unit)
1Unit
-
N/A
Displa
y
param
eter
PST
P18
09
Electrical angle
0.0~360.0 degree
0.1
degree
-
N/A
Displa
y
param
eter
PST
P18
10
Mechanical
angle
(based encoder zero
point)
0.0~360.0 degree
0.1
degree
-
N/A
Displa
y
param
eter
PST
P18
11
Reserved parameter
1
-
N/A
Reser
ved
param
eter
PST