56
Menu Operation
Menu Item 16 [CONTRAST]
Function
: Setting of the display contrast level.
Available Values
: 1 ~ 12
Default
: 5
Menu Item 17 [CW DELAY]
Function
: Set the receiver recovery time during pseudo-VOX CW semi-break-in opera-
tion.
Available Values
: 10 ~ 500 msec
Default
: 250 msec
The recovery time may be adjusted in steps of 10 msec. A longer delay may be preferable
if you pause frequently while sending.
Menu Item 18 [CW ID]
Function
: Enables/disables the CW identifier during ARTS operation.
Available Values
: OFF/ON
Default
: OFF
Menu Item 19 [CW PADDLE]
Function
: Select the keyer paddle’s wiring configuration.
Available Values
: NORMAL/REVERSE
Default
: NORMAL
NORMAL: Keyer paddle polarity is normal. The “tip” plug connection produces dots, and
the “ring” plug connection produces dashes.
REVERSE: Keyer paddle polarity is inverted. The “tip” paddle produces dashes, and the
“ring” paddle produces dots.
Menu Item 20 [CW PITCH]
Function
: Setting of the pitch of the CW sidetone, BFO offset, and CW filter center fre
-
quencies.
Available Values
: 300 ~ 1000 Hz
Default
: 700 Hz
The CW pitch may be adjusted in steps of 50 Hz.
Menu Item 21 [CW SPEED]
Function
: Set the sending speed for the built-in Electronic keyer.
Available Values
: 4wpm ~ 60 wpm/20cpm ~ 300 cpm
Default
: 12 wpm (60 cpm)
You can set the sending speed according to either of two units of speed (wpm: words per
minute; cpm: characters per minute). To switch units between “wpm” and “cpm,” just press
the
knob.