SonTek – a Xylem brand
FlowTracker2 User’s Manual (January 2019)
161
Parameter
Min
Max
Default
Decimals
Units
Required
Measurement Depth
0
100
empty
3
m or ft
Yes
Comment
0
250
empty
No
Delete Station
9.3.1.2
Deleting
a station is performed from the
Data Collection Window
by selecting the
station within the viewable window.
The station delete process is not reversible and the user must ensure that the correct
station is selected. Selected station will be highlighted with a yellow background.
Delete Station
is performed from the
Data
Collection Window
. Up to ten completed stations
will be displayed at any time,
a)
To select a station,
i).
Use the up or down arrow key to scroll through
the completed stations,
b)
To
DELETE
a station,
i).
Press the backspace key.
ii).
The software will navigate to the Confirmation
screen.
Figure 9:9 - Select Station
Confirmation
screen requests confirmation of
deleting the selected station.
a)
To confirm station delete,
i).
Press the Right Soft Key,
b)
To
CANCEL
station delete,
i).
Press the Left Soft Key,
c)
The software will navigate to the Data Collection
Window.
Figure 9:10 - Confirm Delete
Station Measurement (Wading Rod)
9.3.2
Station Measurement
is performed at each Station based on measurement
requirements. The measurement locations can either be structured such in laboratory
environment where the position of the instrument is determined accurately or random
where velocities on channel banks are investigated. The station measurements consist
of collecting a number of different parameters and variables required by the General
mode.
Содержание SonTek FlowTracker2
Страница 107: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 106 ...
Страница 117: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 116 ...
Страница 196: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 195 ii Stationary Measurement ...
Страница 198: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 197 Measurement File Framework 12 1 1 ...
Страница 216: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 215 Variable Mode Description measurement ...
Страница 247: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 246 Configuration Changes ...
Страница 280: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 279 Figure 14 36 Edit by Station Edit a Station ...
Страница 283: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 282 ...
Страница 299: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 298 Appendix A Software Flow Diagram ...
Страница 300: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 299 ...