Save value? appears.
e) Press OK.
Value saved! appears.
5. Select one of the steps:
Condition
Action
The network consists of several subnets. Edit the IP address of the router in the Ethernet Gateway 2.15.18
menu.
The network has no subnets.
-
6. Restart the base unit.
6.7 Connect a computer to the web tool through a LAN
Contact the local network administrator for the compliant settings.
1. Set the IP address of the base unit.
Set the IP address with the web tool
address with the operator panel
2. Connect the base unit to the LAN with an Ethernet cable.
Use a CAT5 patch cable with RJ45 plugs.
3. Connect the computer to the LAN with an Ethernet cable.
WS009547A
4. Start the web browser.
5. Enter the IP address of the base unit in the address text box and press the enter key.
6. Click Login.
WS009546A
7. Enter the User name and the Password.
The default user name is config and the default password is ef56.
8. Click OK.
The Quick overview window opens.
6 System Setup
MAS 711 Installation, Operation, and Maintenance Manual
23