Sensor
Wire number
Base unit terminal
FLS - Leakage, stator housing
1
13
2
14
Pt100 - Temperature measurement, main bearing
3
8
4
4
Thermal switches - Temperature guard, stator windings
5
1
6
2
FLS - Leakage, junction box
7
15
(2)
(14)
Pt100 - Temperature measurement, stator winding phase 1
8
3
(4)
(4)
Pt100 - Temperature measurement, stator winding phase 2
13
5
14
7
Pt100 - Temperature measurement, stator winding phase 3
15
6
16
7
Pt100 - Temperature measurement, support bearing
17
9
18
10
CLS - Leakage, oil housing
19
17
20
16
VIS 10 - Vibration sensor
21
18
22
19
2. Connect the pump memory.
Function
Wire number
Base unit terminal
RS-485 B
9
38
RS-485 A
10
37
Supply, ground (earth)
11
36
Supply, +12 V
12
35
3. When applicable, connect the cable screen to the ground (earth) terminals in the
pump and in the electrical cabinet.
5.2.3 Connect a 12-wire cable from a midrange pump
1. Connect the sensor wires.
Sensor
Wire number
Base unit terminal
FLS — Leakage, stator housing
1
17
2
16
Pt100 — Temperature measurement, main bearing
3
8
4
4
Thermal switches — Temperature guard, stator windings
5
1
6
2
Pt100 — Temperature measurement, stator winding phase 1
8
3
(4)
(4)
2. Connect one of the following sensors:
5 Electrical Installation
MAS 711 Installation, Operation, and Maintenance Manual