Chapter 6 - 16-Bit Ethernet Installation (XVME-956/411)
6.4 I N T E R F A C E CONNECTORS
The following paragraphs explain the different connectors:
10BASE2
When the BNC connector is used, a BNC TEE must be connected to the XVME-956/411's BNC
connector if the Ethernet coax does not end at the XVME-956/411. I f the coax ends at the XVME-
956/411, a 50 Ohm terminator must be installed. This terminator can be a BNC terminator if the BNC
TEE is used or the internal XVME-956/411 termination option can be used.
10BASET
When twisted pair networks are used, a 10BaseT hub must be supplied. Yo u cannot simply connect
from one interface card to another when twisted pair cable is used.
AUI
This connector is provided to external transceivers. This connector is a female D-SUB connector with
a pinout that matches the AUI standard pinout. 12 V power on the AUI connector is directly connected
to the PC/104 bus 12 V system power.
6-10