Operation

Overview

The main goal of the XPAND Trinity 3D Superlight Polarizer is to modulate the light coming from the projector in a way which enables 3D 
viewing in combination with circular polarized passive 3D glasses. The modulation must be done in synchronization with the projector and 
in a way that results in as little light as possible being lost. To achieve synchronization with the projector a 3D synchronization signal is fed 
from the projector to the unit using one of the cables supplied with the product.
Much of the unit’s operation can be configured over the network by using a dedicated PC-based configuration utility. See the 

Unit Config-

uration Using the PC Based Configuration Utility

 section of this manual for more information.

Factory Reset

At any time the XPAND Trinity 3D Superlight Polarizer can be reset to its factory default settings by following these steps:
(1) Unplug all cables from the unit.
(2) Short pins 3 and 4 of the unit’s GPIO port.
(3) Plug the power back into the unit.
(4) Both LEDs on the unit should now be flashing quickly, indicating that a factory reset is about to be done.

 

»

To confirm the factory reset, remove the short circuit between pins 3 and 4. The unit will make two more slow flashes with 
both LEDs to indicate, that a reset has been made.

 

»

To abort a factory default reset, unplug the power cord from the unit and 

only then

 remove the short circuit.

A reset is especially useful when performing network settings configuration if a mistake is made. A Factory Reset will return the unit to its 
factory default settings, making it again accessible at its default IP of 192.168.0.250.
Note that all network settings of the unit will be reset so if they have been previously modified, the unit will now no longer be reachable and 
the network settings should be reconfigured. See section 

Unit’s Initial Network Settings Configuration

 for more information.

Modes of Operation

The Trinity Polarizer operates in one of two modes: 2D mode or 3D mode. As their names suggest, the 3D mode is intended for watching 3D 
content and 2D mode for viewing 2D content at which point the polarizer should be removed from in front of the projector.
Which mode the unit should be operating in is determined by different conditions which depend on which mode control source is selected. 
See section 

Mode Control Sources

 for more information.

The unit signals if it is in 2D or 3D mode through its SYNC / 3D MODE LED and through its Motion Control Output. If the LED is ON, the unit 
is always in 3D mode and is modulating the incoming light, thus making 3D viewing possible. If the LED is OFF, 3D viewing is not possible. 
However the unit may still be operating in 3D mode but no valid 3D synchronization signal is fed to the unit from the projector.
The best way to determine whether the unit is operating in 2D or 3D mode is to connect to it by using the PC-based Configuration Utility 
and have a look at the 

Current Mode

 parameter.

2D Mode

In 2D mode the unit stops modulating the incoming light and sets its Motion Control Output to 2D state (see section 

Motion Control Output

 

for more details). A 2D state on the Motion Control Output triggers the movement of the unit away from the projector, if mounted onto a 
motorized mount connected to this output.
In 2D mode the SYNC/3D MODE LED state depends on which mode control source is currently selected. If the “frame sync” mode control 
source is selected, the LED is flashing slowly thus indicating, that the unit is not detecting a valid 3D synchronization signal. For other mode 
control sources the LED is OFF when in 2D mode. See 

LED Indications

 and 

Mode Control Sources

 sections of this manual for more 

information.
While in 2D mode, the unit continuously scans for conditions to transition to 3D mode. These conditions depend on which mode control 
source is selected - refer to section 

Mode Control Sources

.

3D Mode

In 3D mode the unit sets its Motion Control Output to 3D state (see section 

Motion Control Output

 for more details). A 3D state on the Mo-

tion Control Output triggers the movement of the unit in front of the projector, if mounted onto a motorized mount connected to this output.

Содержание XPAND 3D

Страница 1: ...XPAND Trinity 3D Superlight Polarizer User Manual to be used on dark background to be used on light background...

Страница 2: ......

Страница 3: ...2 Installation 12 Motion Control Setup Wizard 13 Unit s Initial Network Settings Configuration 13 Adjusting the Image Position 15 Recommended Projector Settings for XPAND Passive 3D Cinemas 17 Unit Co...

Страница 4: ......

Страница 5: ...d instructions for proper use of the product Do not copy bind or distribute Please check to see if this product is working properly upon receipt System Overview The XPAND Trinity 3D Superlight Polariz...

Страница 6: ...ndicating which mode the unit is currently operating in A B C D E F G H I J 1 2 3 4 5 6 System Parts Important parts of the XPAND Trinity 3D Superlight Polarizer are shown in below image This image is...

Страница 7: ...section Modes of Operation for more details LED indications given in below table can be encountered For more information about different states corresponding to below LED indica tions see the rest of...

Страница 8: ...of two modes 2D mode or 3D mode As their names suggest the 3D mode is intended for watching 3D content and 2D mode for viewing 2D content at which point the polarizer should be removed from in front...

Страница 9: ...Frame Sync mode control source is selected Frame Sync Mode Control Source The default way of determining whether the unit must begin operating in 3D mode is to monitor the 3D synchronization signal l...

Страница 10: ...nd macro string mode 3D The 2D and 3D macros are not the only ones which are accepted by the XPANDTrinity 3D Superlight Polarizer however they are the two most typically used ones Table 2 below summar...

Страница 11: ...ay when sending the macro over the network which gives the unit enough time to receive the command before the server disconnects An example of a macro which puts the unit in 3D mode if the Network Mod...

Страница 12: ...rojector and to the 9 pin GPIO connector on the back of the Trinity Polarizer Two cables are supplied with the unit Choose the correct one based on the available connectors on the projector 5 If the u...

Страница 13: ...content 6e Both the green and yellow LED on the Trinity Polarizer need to be turned ON If the mount starts moving wait for it to stop 6f At this point the unit must be located in front of the projecto...

Страница 14: ...is reserved network configuration is finished If however more devices will be connected to the same network this unit s IP must be changed since each device requires a unique IP Proceed to step numbe...

Страница 15: ...Click the Add new device link and enter a device name its new IP and make sure the port is set to 1000 An attempt to connect to this device will then be made If you were configuring the unit by direc...

Страница 16: ...exist and any one of them can be used for calibration of the Trinity Polarizer However some images are more appropriate than others It is suggested that XPAND s dedicated 3D calibration image shown in...

Страница 17: ...is adjustment is mostly seen with short throw projectors and that the adjustment is usually only noticeable in the corners of the image Figure 17 Central Image Scale Zoom Adjustment using Screw H Once...

Страница 18: ...For a more detailed and up to date explanation see the configuration utility s help file Device Selection and Connection In a common setup a cinema theatre will have more than one cinema hall equipped...

Страница 19: ...e General Settings This section displays and enables modification of general settings of the connected device 3D Sync Signal Polarity Can be used to determine and change the interpretation of the inco...

Страница 20: ...and only the functional ones are reset Resetting also the network settings would very likely make the unit not accessible on the network without repeating the initial network settings configuration ag...

Страница 21: ...60 Hz 72 Hz triple flash 24 Hz cinema 96 Hz double flash 48 Hz HFR cinema 120 Hz double flash 60 Hz HFR cinema Input Terminal 3D GPIO 9 pin DB9 male connector Converter cables to DB15 and DB37 connect...

Страница 22: ...tinued in case adults or children experience any of the following symptoms dizziness altered vision eye or muscle twitching involuntary movements loss of awareness unconsciousness disorientation or se...

Страница 23: ...o the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Hereby...

Страница 24: ......

Отзывы: