XT2500 Product Manual
Page 88 | 92
CONFIDENTIAL AND PROPRIETARY
Command
Function
:rrval flags
Read user script flags
:rrval uservar <type> <index>
Read a uservar
:rrval timer <index>
Read remaining time
:rrval gfnstat
Read geofence active & inside status bitfields
:wrval odom <index> <value>
<value> must be larger than current value:
Index
Description
0
GPS Trip 1
1
GPS Trip 2
2
OBD Trip
3
GPS Life
4
OBD Life
:crval tripodom <index>
Clear a trip odometer:
Index
Description
0
GPS Trip 1
1
GPS Trip 2
2
OBD Trip
:wrval flags <value>
Write user script flags
:wrval uservar <type> <index>
<value>
Write a uservar
:drtask
Suspend interpreter task
:ertask
Resume interpreter task
:urcmd bs <packet id>
<reason code> <dst index>
<ack> <qty>
Force a build and send of a packet (any reason code less than 0 or greater
than 255 will wrap)
NOTE: <qty> only available on engineering devices
:rrval linkver
Read linkage version information (See TBD; formerly Linkage Version)
6.6.16. Main Processor
Command
Function
:d1dbg [<lock_code>]
Lock-out JTAG (disable debug); two stage command:
1. Issue :d1dbg (returns <lock_code>)
2. Issue :d1dbg <lock_code>
:g1bl x <serial_port_id>
Upgrade main bootloader via xmodem
:g1fw x <serial_port_id>
Upgrade main firmware via xmodem
:q1fw/:q1i
Query main firmware
:u1cmd reset
Reset main processor