XT2500 Product Manual
Page 13 | 92
CONFIDENTIAL AND PROPRIETARY
4.6. B
UZZER
S
ONGS
(
BZR
)
The
Buzzer Songs
configuration sets the frequency and duration of up to 8 notes on the device buzzer.
Configuration instances: 10
Command Type
Syntax
SET
Command
:wycfg bzr[x] <frequency1> <duration1> ... <frequency8> <duration8>
Response
:OK
READ
Command
:rycfg bzr[x]
Response
| bzr[x]: freq1:<frequency1> (hex_val), dur1:<duration1> (hex_val), ...
freq8:<frequency8> (hex_val), dur8:<duration8> (hex_val)
:OK
Param
Range
Description
frequencyX
0 to 65535
A frequency that corresponds to the Xth note to be played (Hz); 0 is silent.
durationX
0 (disable),
10-6535
The duration of the Xth note to be played (ms)
4.7. D
ESTINATION
(
DST
)
The dst[9] instance is utilized for all Device Manager interactions, including device Checkin Messages; configure
accordingly.
Configuration instances: 10
Command Type
Syntax
SET
Command
:wycfg dst[x] "<ip>|<hostname>|<local serial>" <port_number>
Response
:OK
READ
Command
:rycfg dst[x]
Response
| dst[x]: addr:"<ip>|<hostname>|<local serial>" port:<port_number> (hex_val)
:OK