107
long time
large
22
0
E-220
Absolute
encoder
communicati
on error
1.
Encoder
not
connect or contactor
not good
Cut off drive power, check
encoder wiring, use
multi-meter test the
connection
2. recived encoder
data error, and error
time over encoder
error time register
P0-56 value
Not put the encoder wire
together with the strong power
supply cable, install filter at
servo drive power supply
input side, install magnet ring
around encoder wire, far away
from large noise equipment
2
E-222
Absolute
encoder
battery
voltage low
The battery voltage
is lower than 2.75V
Please change new battery
when the servo power is on,
the battery is no.5 3.6V
3
E-223
Absolute
encoder data
visit alarm
Encoder problem, or
power supply is not
stable
Unplug the encoder cable
without battery will alarm
4
E-224
Absolute
encoder
overspeed
Large
change
of
encoder data
Unplug the encoder cable
without battery will alarm
26
0
E-260
Over
range
alarm
Check
the
over
range signal and the
over range mode is
alarm
If it no need to alarm after
over range, user can change
the over range signal mode
1
E-261
Over
range
signal
1. motor run forward
and encounter the
Check
the
over
range
connection and over range
Содержание DS3 series servo
Страница 1: ...DS3 DS3E series servo drive Fast manual Wuxi Xinje Electric Co Ltd Data No SC301 20171206 1 0...
Страница 2: ......
Страница 4: ......
Страница 30: ...24 90 series servo motor dimension Unit mm Model LA Normal With brake MS 90ST M02430 20P7 149 194...
Страница 34: ...28 3 2 Servo drive DS3 20P2 4 7 PQA DS3E 20P2 4 7 PFA Unit mm 70 0 186 0 166 0 59 0 175 0...
Страница 59: ...53 4 7 Wiring example Take DS3 21P5 PQA as an example...
Страница 118: ......
Страница 119: ......