104
limit
limit P0-23
11
0
E-110
Motor UVW
short circuit
Not match the motor
code
Drive P0-33 must match the
motor code on the motor label
U, V, W wiring error
Check UVW phase wiring
Short circuit with
drive UVW or motor
problem
1. measure the phase resistor
of motor phase UVW, if not
balanced, change the motor
2. If short circuit between
UVW and PE, change the
motor 3. Measure UVW
output with multimeter (diode
gear), black pen test P+, red
pen test UVW, red pen test P-,
black pen test UVW. 6. Group
voltage any one is 0, change
the drive
Load
has
locked
rotor
Run the motor without load to
check the problem
Alarm
at
the
moment
of
high-speed stop/start
Increase the acceleration time
Encoder problem
1. Check encoder cable or
change it 2. Set servo to bb
state, monitor U0-10, rotate
motor shaft by hand, U0-10
increase at one direction and
decrease at another direction
(0~9999)