108
connection
error
reverse over range
signal
2. motor run reverse
and encounter the
forward over range
signal
terminal distribution
2
E-262
Control stop
over time
1. inertia too big
2. stop overtime too
short
3. brake torque too
small
1. decrease the inertia or use
motor with brake
2. increase stop overtime
P0-30
3. increase brake torque P3-32
28
0
E-280
Vibration too
serious
Motor vibration too
serious
Decrease servo position loop
or speed loop gain, check the
motor shaft connection
30
0
E-300
Motion
bus
lose
synchronizati
on
Motion
bus
communication error
Check
the
motion
bus
connection
31
0
E-310
Motor
code
error
Motor code error
Set the correct motor code
1
E-311
Motor
code
lost
Motor code not set
Set motor code in P0-33
9. General debug steps
(A) Before power on, check the product according to the inspection of the goods described in
the manual to confirm that the equipment is not obviously damaged.
(B) In the absence of obvious damage, connect the servo drive and servo motor, and
Содержание DS3 series servo
Страница 1: ...DS3 DS3E series servo drive Fast manual Wuxi Xinje Electric Co Ltd Data No SC301 20171206 1 0...
Страница 2: ......
Страница 4: ......
Страница 30: ...24 90 series servo motor dimension Unit mm Model LA Normal With brake MS 90ST M02430 20P7 149 194...
Страница 34: ...28 3 2 Servo drive DS3 20P2 4 7 PQA DS3E 20P2 4 7 PFA Unit mm 70 0 186 0 166 0 59 0 175 0...
Страница 59: ...53 4 7 Wiring example Take DS3 21P5 PQA as an example...