61
U0-54
Reserved
U0-55
Instantaneous regenerative braking discharge power
U0-56
Average regenerative braking discharge power
U0-57
Absolute encoder present
position feedback
(0000~9999)*1
Encoder pulse
U0-58
(0000~65535)*10000
U1-XX
:
Number
Contents
Unit
U1-00
Current alarm code
U1-01
Current warning code
U1-02
U phase current when alarming
0.01A
U1-03
V phase current when alarming
0.01A
U1-04
Bus voltage when alarming
V
U1-05
IGBT temperature when alarming
0.1
℃
U1-06
Q axis current (torque current) when alarming
0.1A
U1-07
Excitation current when alarming
A
U1-08
Position offset when alarming
Command
pulse
U1-09
Speed value when alarming
rpm
U1-10
The alarm occurred time second (low 16 bits), count
from power on
s
U1-11
The alarm occurred time second (high 16 bits), count
from power on
s
U1-12
Run error times, count from power on
U1-13
Warning times, count from power on
U1-14
History alarm times
U1-15
History warning times
U1-16
The second time alarm code recently