KCU1250 User Guide
74
UG1057 (v1.0) December 19, 2014
Appendix D:
System Controller
GPIO Data Menu
The system controller continuously scans specific user activated inputs and several onboard
status signals. Positions 1 - 4 (ADDR3, ADDR2, ADDR1, ADDR0) of address DIP switch SW13
are monitored, as well as five user pushbuttons (SW5, SW6, SW10, SW11, SW12).
GPIO Menu Options
KCU1250 System Controller
- GPIO Menu-
1. Get GPIO PL Data
2. Continuous Scan GPIO Readings
0. Return to Main Menu
Select an option
• Get GPIO PL Data
The signals monitored with this option are currently not available in the KCU1250 board.
----------------------
FMC1_PRSNT = NO
FMC2_PRSNT = NO
PMBUS_CABLE_B = NO
FPGA_IIC_BUSY = NO
PMBUS_ALERT = No
• Continuous Scan GPIO Readings
Press any Key to Return to GPIO Menu
When any of the address DIP SW13 poles 1-4 are changed, or a pushbutton pressed, the
value beneath the switch position changes accordingly (showing a 0 or a 1).
SYS ADDR (SW13) (ADDR3, ADDR2, ADDR1, ADDR0)
0 0 0 0
Pushbuttons (SW11, SW12, SW5, SW6, SW10)
0
0
0
0
0
----------------------
FMC1_PRSNT = NO
FMC2_PRSNT = NO
PMBUS_CABLE_B = NO
FPGA_IIC_BUSY = NO
PMBUS_ALERT = NO