High Capacity Feeder Option
12.6.2 Elevator Motor Assembly
1. Disconnect the AC power and remove the Rear Access Cover.
2. Reconnect the AC power and measure the voltage from J2 pin 1 to
frame ground. The voltage is +24.0 +/- 1.0 VDC.
Y:
Go to step 3.
N:
Replace the Power Supply (12.2.2).
3. Disconnect the AC power. Disconnect P/J2 from the Controller PWB.
Make the measurements listed in Table 1. All measurements are
correct.
Y:
Go to step 4.
N:
Replace the Elevator Motor Assembly (12.2.3):
.
4. Reconnect P/J2 and disconnect P/J3. Measure the resistance between pins 5
and 6 on the disconnected plug. The resistance is 0 (zero) ohms with the feeder
drawer open, and infinite with the drawer closed
Y:
Go to step 5.
N:
Check the wiring between the Elevator Interlock Switch and P3. If OK,
replace the switch (12.2.4).
5. Measure the resistance between pins 3 and 4 on P3. The resistance is 0 (zero)
ohms with the Lower Limit Switch actuated, and infinite with the switch
deactuated
Y:
Go to step 6..
N:
Check the wiring between the Lower Limit Switch and plug P3. If OK,
replace the switch (12.2.4).
6. Replace the Controller PWB (12.2.3).
Table 12.6.2.1 Table 1. Elevator Motor
From
To
Reading
P2 Pin 1
P2 Pin 3
30 +/- 3 ohms
P2 Pin 1
P2 Pin 5
30 +/- 3 ohms
P2 Pin 2
P2 Pin 4
30 +/- 3 ohms
P2 Pin 2
P2 Pin 6
30 +/- 3 ohms
J6
J5
J4
J3
J8
J9
J2
J1
J7
Denotes Pin #1
RAP_01
6
1
P2
WIR_P2b
8
1
P3
WIR_P3b
www.printcopy.info