Device Menu
975-0400-01-01
3–19
Table 3-8
Device Menu Values
Setting
Values
Default
Description
Mode
Operating
Operating,
Standby,
Hibernate
Operating
Operating
is the normal mode for the
unit.
Standby
disables the output by
disconnecting the main power circuit
from the battery. The unit cannot
charge. The unit still draws some
power from the battery to operate.
The LCD stays on.
Hibernate
performs the same actions
as Standby, but it also disables all
Xanbus network communications.
System ID
548973135
n/a
n/a
Xanbus system ID.
Device Number
00
00 to 31
00
Displays the device number for the
XW SCC. This number is selected
when the XW SCC is first powered
up, and uniquely identifies devices of
the same type (Charge Controllers,
Inverter/Chargers, control panels, and
so on) in a networked installation.
Version
01.00
Build
0005
n/a
n/a
Firmware version and firmware build
number. This screen is identical to the
screen shown at startup.
Copy Setup From?
01
All
available
device
numbers.
01
Enables one-step configuration of a
new XW SCC in a multi-unit
installation. Select the device number
of the unit you wish to copy the setup
from. This screen is hidden when no
compatible devices are found.
The “Copy Setup From?” command
copies all Battery Menu settings and
Custom Battery Menu settings from
the selected unit.