Configuration
3–12
975-0400-01-01
Configuring the Auxiliary Output
The Aux Menu allows you to enable and configure the auxiliary output. The
auxiliary output provides between 5 and 13 volts DC (configurable) and up to 200
milliamps to power a relay, indicator light, vent fan, or alarm.
The Aux Menu is an Advanced Menu item. To display the Aux Menu, go to the
Display Menu, view the Display Mode screen and select Advanced. See
“Configuring the LCD” on page 3–16.
Figure 3-5
Aux Menu
Table 3-5
Aux Menu Values
Setting
Values
Default Description
Aux Control Mode
ManualOff
Manual Off,
Manual On,
Automatic
Manual
Off
Sets the operating mode for the
auxiliary output. When set to
Automatic, the auxiliary output
will turn on or off according to the
selected Trigger Source. You can
turn the auxiliary output on or off
at any time by selecting ManualOn
or ManualOff.
Advanced menu
=
AUX MENU
Trigger Source
Low Batt Voltage
Trigger 10.0
Clear 12.0
Output Level
12V
Output Mode
Active Hi
Trig Delay 01:01
Clr Delay 01:01
Aux Control Mode
Manual Off
Enter
Exit
Appears if a related setting
is enabled or as allow ed
by the installation
=
Содержание XW-MPPT60-150