Operator Interface
153378
2–13
Table 2-2
Read Menu Descriptions
Operational Parameter
Description
ID
Units
Current Operating State
Displays as:
System: *
where * can be any one of the states
listed in the description for this
parameter.
Current system states include the following.
Initializing (0)
Switched Off(1)
Shutdown (2)
Starting (3)
PWR Tracking (4)
Manual Current (5)
Matrix Test (6)
Faulted (7)
1
N/A
System Goal State
Displays as:
Goal: *
where * can be any one of the states
listed in the description for this
parameter.
Goal States include the following.
Shut Down (2)
PWR Tracking (4)
Manual Current (5)
Matrix Test (6)
2
N/A
Fault code
See “Fault Code Descriptions” on page 4–5 for a detailed
list of Fault Codes.
3
N/A
Inverter State
Displays as:
Inverter: *
where * can be any one of the states
listed in the description for this
parameter.
Inverter States includes the following.
Shutdown (0)
Stand-by (1)
Starting (2)
Main-Settling (3)
On-Line (4)
4
N/A
Line A–B voltage
Displays as:
INV A volts: xxx
AB Line to line voltage
5
V
rms
Line B–C voltage
Displays as:
INV B volts: xxx
BC Line to line voltage
6
V
rms
Line C–A voltage
Displays as:
INV C volts: xxx
CA Line to line voltage
7
V
rms
Phase A current
Displays as:
INV A amps: xxx
Phase A current
8
A
rms
Phase B current
Displays as:
INV B amps: xxx
Phase B current
9
A
rms
Содержание GT100-208
Страница 1: ...Xantrex GT100 Grid TiedPhotovoltaic Inverter Operation and Maintenance Manual GT100 208 GT100 480 ...
Страница 2: ......
Страница 3: ...Xantrex GT100 Grid Tied Photovoltaic Inverter Operation and Maintenance Manual ...
Страница 8: ...vi ...
Страница 15: ...Safety 153378 xiii Figure i AC Utility Terminals Figure ii DC Terminals TB1 N A TB2 B C TB5 PV GND TB3 TB4 ...
Страница 20: ...xviii ...
Страница 22: ...xx ...
Страница 24: ...xxii ...
Страница 46: ...1 22 ...
Страница 94: ...4 14 ...
Страница 108: ...B 2 ...
Страница 110: ...B 4 ...
Страница 117: ......