Operation
Power Supply Operation
54
Operating Manual for Multichannel Functionality (GPIB-M)
Clear
Protection
Event
If the unit has shut down, resume operation by sending the "
OUTP ON
" command.
To support older revisions of firmware (1.5 and older),
[:]OUTPut[<channel>]:PROTection:CLEar
command will still be
parsed and passed to other instruments on the CANbus.
Shutdown vs
Protection
Alarm
If a protection setpoint is exceeded, the system does the following:
1. If
:STATe
has been set to ON, the unit shuts down.
(OVP does not have a settable :STATe. It is always ON.)
2. If
:STATe
has been set to OFF, the unit does not shut down but creates an alarm
by setting the appropriate bit in the questionable status register, which can be
queried remotely. See
“Status Registers” on page 69
for more information.
WARNING- Fire Hazard
If an over-voltage or over-current protection error persists without apparent cause,
disable the output, and turn the AC switch OFF. Inspect the load and power supply
for evidence of an electrical fault. The power supply should not be brought back into
operation if there is any evidence of an electrical fire or other safety hazards.
Содержание GPIB-M-HPD
Страница 2: ......
Страница 18: ...List of Figures xvi Operating Manual for Multichannel Functionality GPIB M...
Страница 26: ...Features and Specifications Specifications 24 Operating Manual for Multichannel Functionality GPIB M...
Страница 94: ...Current Sharing Operation 92 Operating Manual for Multichannel Functionality GPIB M...
Страница 98: ...GPIB Performance Specifications 96 Operating Manual for Multichannel Functionality GPIB M...
Страница 118: ...SCPI Command Reference Expressions 116 Operating Manual for Multichannel Functionality GPIB M...
Страница 132: ...Calibration Restore Factory Calibration 130 Operating Manual for Multichannel Functionality GPIB M...
Страница 133: ......