Features and Specifications
Specifications
22
Operating Manual for Multichannel Functionality (GPIB-M)
Table 1.4
Specifications for XHR 1000 W with GPIB-M or CANbus
Models
7.5-130
20-50
33-33
40-25
60-18
Program Resolution
Voltage
Current
1.16mV
42.0mA
1.8mV
30.8mA
3.08mV
18.2mA
6.2mV
9.8mA
9.2mV
6.44mA
Program Accuracy
1
Voltage
Current
10mV
±0.12%
900mA
±0.1%
50mV
±0.12%
750mA
±0.1%
75mV
±0.12%
500mA
±0.1%
75mV
±0.3%
350mA
±0.1%
150mV
±0.25%
250mA
±0.1%
Readback Resolution
Voltage
Current
1.16mV
42.0mA
1.8mV
30.8mA
3.08mV
18.2mA
6.2mV
9.8mA
9.2mV
6.44mA
Readback Accuracy
1
Voltage
Current
30mV
±0.12%
900mA
±0.1%
60mV
±0.12%
750mA
±0.1%
75mV
±0.12%
500mA
±0.1%
75mV
±0.3%
350mA
±0.1%
150mV
±0.25%
250mA
±0.1%
Models
100-10
150-7
300-3.5
600-1.7
Program Resolution
Voltage
Current
15.4mV
3.92mA
23.1mV
2.52mA
46.2mV
1.26mA
92.4mV
0.56mA
Program Accuracy
1
Voltage
Current
1.
Apply accuracy specifications according to the following voltage program accuracy example:
Set a model XHR 20-50 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 50mV ± 0.12% of the set voltage of 10 volts.
150mV
±0.35%
140mA
±0.15%
225mV
±0.35%
120mA
±0.1%
225mV
±0.35%
80mA
±0.1%
250mV
±0.35%
80mA
±0.1%
Readback Resolution
Voltage
Current
15.4mV
3.92mA
23.1mV
2.52mA
46.2mV
1.26mA
92.4mV
0.56mA
Readback Accuracy
1
Voltage
Current
150mV
±0.35%
140mA
±0.15%
225mV
±0.35%
120mA
±0.1%
225mV
±0.35%
80mA
±0.1%
250mV
±0.35%
80mA
±0.1%
Содержание GPIB-M-HPD
Страница 2: ......
Страница 18: ...List of Figures xvi Operating Manual for Multichannel Functionality GPIB M...
Страница 26: ...Features and Specifications Specifications 24 Operating Manual for Multichannel Functionality GPIB M...
Страница 94: ...Current Sharing Operation 92 Operating Manual for Multichannel Functionality GPIB M...
Страница 98: ...GPIB Performance Specifications 96 Operating Manual for Multichannel Functionality GPIB M...
Страница 118: ...SCPI Command Reference Expressions 116 Operating Manual for Multichannel Functionality GPIB M...
Страница 132: ...Calibration Restore Factory Calibration 130 Operating Manual for Multichannel Functionality GPIB M...
Страница 133: ......