2-2
Unit Description
2.2. RSM-8R4 Series - Back Panel Components
As shown in Figures 2.2 and 2.3, the back panel on RSM-8R4 series units includes the
following components:
Power Inlet:
An IEC320-C14 AC inlet which supplies power to the RSM-8R4's
control functions and switched power outlets. Also includes cable keeper
(not shown.)
Circuit Breaker:
The circuit breaker is rated as follows:
•
RSM-8R4-1:
15 Amp Circuit Breaker.
•
RSM-8R4-2:
10 Amp Circuit Breaker.
Switched Outlets:
Four AC Outlets that can be switched On, Off or rebooted in
response to user commands:
•
RSM-8R4-1:
Four (4) each, NEMA 5-15R Outlets.
•
RSM-8R4-2:
Four (4) each, IEC320-C13 Outlets.
Serial Ports:
For connection to console ports on target devices. Standard RJ45
connectors configured as DCE ports. For more information on connecting devices
to the serial ports, please refer to Section 4.5 and Appendix B. For a description of
the serial port interface, please refer to Appendix A.1.
Power On/Off Switch
Network Port:
An RJ45 Ethernet port for connection to your 10Base-T or
100Base-T, TCP/IP network. Note that the RSM-8R4 features a default IP address
(192.168.168.168). This allows you to connect to the unit without first assigning an
IP address. The Network Port also includes two LED indicators for Link and Data
Activity. For more information on port configuration, please refer to Section 5.9.
Internal Modem Port:
For connection to your external phone line. For more
information on Modem Port configuration, please refer to Section 5.8.
I
PLUG 1
PLUG 2
PLUG 3
PLUG 4
Ethernet 10/100
PHONE LINE
ACT
LINK
O
SETUP
PORTS
SERIAL PORTS
1
2
3
4
5
6
7
Figure 2.2: RSM-8R4-1 - Back Panel
Figure 2.3: RSM-8R4-2 - Back Panel
I
PLUG 1
PLUG 2
PLUG 3
PLUG 4
Ethernet 10/100
PHONE LINE
ACT
LINK
O
SETUP
PORTS
SERIAL PORTS
1
2
3
4
5
6
7