![Worldwide Construction And Forestry Division 380GLC Скачать руководство пользователя страница 93](http://html1.mh-extra.com/html/worldwide-construction-and-forestry-division/380glc/380glc_operators-manual_998038093.webp)
Operation—Monitor Operation
OUT4001,0000728 -19-28FEB12-1/1
Main Menu—Setting Menu—Auto Exhaust
Filter Cleaning
CAUTION: Servicing machine during exhaust
filter auto cleaning can result in serious personal
injury. Avoid exposure and skin contact with
hot gases and components.
During exhaust filter auto cleaning, the engine
may run at elevated idle and hot temperatures
for an extended period of time. Exhaust gases
and exhaust filter components may reach
temperatures hot enough to burn people and
ignite or melt common materials.
NOTE: Disabling auto exhaust filter cleaning is not
preferred. Whenever possible, auto cleaning should
be enabled to keep soot buildup to a minimum
and to increase overall machine uptime.
If operating in conditions where it may be unsafe for
elevated exhaust temperatures, auto cleaning of the
exhaust filter can be disabled.
The
Auto Exhaust Filter Cleaning
menu allows the
operator to enable or disable the auto cleaning function
for the exhaust filter.
At Setting Menu, rotate monitor dial to highlight Auto
Exhaust Filter Cleaning. Press monitor dial to display
Auto Exhaust Filter Cleaning menu:
NOTE: When auto cleaning is disabled, the color
of the preceding square is green and exhaust
filter auto cleaning disabled indicator (1) will
appear on the default screen.
When auto cleaning is enabled, the color of
the preceding square is gray and an exhaust
filter cleaning indicator (2) will appear on the
default screen when an auto or parked cleaning
procedure is taking place.
The exhaust filter auto cleaning disabled indicator
will display on the monitor when the key switch is
in ON position. Once the engine is started, the
TX1086450
—UN—06JAN1
1
Exhaust Filter Auto Cleaning Disabled Indicator
TX1086451
—UN—06JAN1
1
Exhaust Filter Cleaning Indicator
1— Exhaust Filter Auto
Cleaning Disabled Indicator
2— Exhaust Filter Cleaning
Indicator
indicator will disappear unless exhaust filter auto
cleaning has been disabled by the operator.
□
OFF (Disable)
Press monitor dial to turn OFF (disable) auto cleaning.
Press monitor dial again to enable auto cleaning.
Press Back button to return to previous screen.
Press Home button to return to default screen.
2-2-18
092221
PN=93
Содержание 380GLC
Страница 6: ...Introduction Continued on next page TX JDEULA 19 11JUL16 2 3 TX1219046 UN 11JUL16 092221 PN 6...
Страница 7: ...Introduction TX JDEULA 19 11JUL16 3 3 TX1219047 UN 14JUL16 092221 PN 7...
Страница 9: ...Introduction DX EMISSIONS EPA 19 12DEC12 2 2 TS1721 UN 15JUL13 092221 PN 9...
Страница 13: ...Introduction Continued on next page DX EMISSIONS CARB 19 26AUG20 4 8 RG29281 UN 27FEB17 092221 PN 13...
Страница 16: ...Introduction Continued on next page DX EMISSIONS CARB 19 26AUG20 7 8 RG32758 UN 19AUG20 092221 PN 16...
Страница 17: ...Introduction DX EMISSIONS CARB 19 26AUG20 8 8 RG32759 UN 19AUG20 092221 PN 17...
Страница 24: ...Introduction 092221 PN 24...
Страница 287: ...Index Index 11 092221 PN 11...
Страница 288: ...Index Index 12 092221 PN 12...