C** SHUTDOWNS **
Figure 3-11. Service: C** SHUTDOWN ** Menu
This menu displays the status of the shutdown modes.
01 SHUTDOWN STATUS
displays the shutdown condition. If the control has shutdowns, it displays
TRUE. If no shutdowns exist, it displays FALSE.
02 FIRST SHUTDOWN
displays the cause of the first shutdown. If the control has a shutdown condition,
this menu item indicates the first shutdown:
NO SHUTDOWN
POWER UP SHUTDOWN
OVERSPEED
BOTH MPU FAIL
ANALOG INPUT #1 FAIL (if configured as such)
ANALOG INPUT #2 FAIL (if configured as such)
MODBUS ISSUED TRIP
TEST MODE
EXTERNAL SHUTDOWN
STUCK IN CRITICAL BAND
03 POWER UP SHUTDOWN (1)
displays the status of power up shutdown. Shutdown is detected when
the power supply to the 2301E-ST is turned off.
04 OVERSPEED (2)
displays the status of overspeed trip. Shutdown is detected when the turbine
reaches an overspeed.
05 BOTH MPU FAIL (3)
displays the status of both MPU fail. Shutdown is detected if both MPU fails.
Released
Содержание 2301E-ST
Страница 15: ...Manual 26694 2301E ST Woodward 13 Figure 2 1a 2301E ST Outline Drawing 8273 1013 1014 Released...
Страница 16: ...Manual 26694 2301E ST Woodward 14 Figure 2 1b 2301E ST Outline Drawing Hazardous Location Version Released...
Страница 17: ...Manual 26694 2301E ST Woodward 15 Figure 2 2a 2301E ST Plant Wiring Diagram sheet 1 Released...
Страница 18: ...Manual 26694 2301E ST Woodward 16 Figure 2 2b 2301E ST Plant Wiring Diagram sheet 2 Released...
Страница 19: ...Manual 26694 2301E ST Woodward 17 Figure 2 2c 2301E ST Plant Wiring Diagram notes Released...
Страница 53: ...Manual 26694 2301E ST Woodward 51 Figure 3 14 Control Gain as a Function of Speed Error Released...
Страница 125: ...Manual 26694 2301E ST Woodward 123 Declarations Released...