FD-6045-CE and FD-8645-CE
Fire Deck Installation and Operation Manual
PG
15
OF
32
M0042.13 JULY 2019
GAS SPECIFICATIONS: FD-6045-CE
WS-FD-6045-RFG-(L
OR
R)-IR-CE-NG MODELS
EN 437 Gas Group
|
2H
|
2L
|
2HS
|
2ELL
|
2EK
Declared Input (kW)
41�39
41�39
41�39
41�39
35
Inlet Pressure (mbar)
20
25
25
20
20/25
Declared
Pressure at
Gas Valve
Outlet (mbar)
SV-1
8�7
8�7
8�7
8�7
8�7
SV-2, 3
12�5
12�5
12�5
12�5
12�5
WS-FD-6045-RFG-(L
OR
R)-IR-CE-LP MODELS
EN 437 Gas Group
|
3+
|
3B/P(30)
|
3B/P(50)
|
3P
Declared Input (kW)
46�85
50
50
46�85
Inlet Pressure (mbar)
28-30/37/50
*
30/37
*
50
*
30/37/50
*
Declared
Pressure at
Gas Valve
Outlet (mbar)
SV-1
19�9
19�9
19�9
19�9
SV-2,3
19�9
19�9
19�9
19�9
NATURAL GAS (NG)
Gas Supply and Pressure
PROPANE (LP)
Gas Supply and Pressure
SCOPE OF APPROVALS
G20/G25.3 @ 20/25 mbar - I
2EK(20)
-
NL
G20 @ 20 mbar - I
2H(20)
-
AT, CH, CZ, DK, EE, ES, FI, GB, GR, HR, HU, IE, IT, LT, LV, NO, PT, RO, SE, SI, SK and TR
G20 @ 20 mbar - I
2HS(20)
-
HU
G20 @ 20 mbar - I
2ELL
-
DE
G20/25 @ 20/25 mbar - I
2E+
-
BE and FR
* Propane (LP): Maximum inlet gas pressure to the oven,
after the external regulator (if used), must not exceed 34 mbar (14" W.C. or 1/2 psi).
Natural Gas (NG): Maximum inlet gas pressure must not exceed 34 mbar (14" W.C. or 1/2 psi)
SCOPE OF APPROVALS
G31 @ 37 mbar
*
- I
3P(37)
-
BE, CH, CZ, ES, FR, GB, GR, HR, IE, IT, LT, NL, PL, PT, SI, SK, TR
G31 @ 50 mbar
*
- I
3P(50)
-
AT, BE, CH, CZ, DE, ES, FR, GB, NL, SK
G30 @ 28-30 mbar, 37 mbar
*
- I
3+(28-30/37)
-
BE, CH, CY, CZ, ES, FR, GB, GR, IE, IT, LT, PT, SI, SK, TR
G30 @ 30 mbar - I
3B/P(30)
-
AT, BE, CY, CZ, DE, DK, EE, FR, GB, HR, HU, IT, LT, NL, NO, PL, RO, SE, SI, SK
G30 @ 50 mbar
*
- I
3B/P(50)
-
AT, CH, CY, CZ, DE, FR, SK
Содержание FIRE DECK 6045
Страница 31: ...PG 31 OF 32 M0042 13 JULY 2019 Blank page ...