FD-6045-CE and FD-8645-CE
Fire Deck Installation and Operation Manual
INSTALLATION CLEARANCES
PG
7
OF
32
M0042.13 JULY 2019
Non-combustible
floor, 915 mm
(36") in front & 762
mm (30") to either
side of oven
doorway
Maintain 610 mm
(24") clearance
from the top
25 mm (1") minimum
side clearance
to combustible
construction
IF THIS OVEN IS NOT PROPERLY INSTALLED A FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THESE
INSTALLATION INSTRUCTIONS. A MAJOR CAUSE OF OVEN RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED
CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF UTMOST IMPORTANCE THAT THIS OVEN BE
INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS.
CLEARANCES
a.
The Wood Stone Fire Deck oven should have a
minimum 25mm (1") clearance to combustibles from all sides, and 610
mm (24") clearance to combustibles from the top.
If building a facade that will contact the oven, use completely non-
combustible materials
*
� Please note that standard Drywall (or Sheetrock) is considered a combustible�
b.
Install this oven only on a non-combustible floor surface� The non-combustible floor surface should extend 915mm (36") out
in front of the oven, and extend 762mm (30") to either side of the oven doorway�
Wood-fired ovens must be installed on non-combustible floor surface AND provided with a non-combustible floor covering at
least 762mm (30") to each side of door opening and 915mm (36") in front of the door opening�
* When noncombustible building materials contact the body of the oven, the respective clearances are
transferred to those non-combustibles.
WARNING:
Installation and servicing of this product could expose you to glasswool/ceramic fibers as
well as calcium silicate dust. ALWAYS WEAR RESPIRATORY AND EYE PROTECTION WHEN INSTALLING
OR SERVICING THIS APPLIANCE. Please read this entire manual before you install the oven. Failure
to follow instructions may result in property damage, bodily injury or even death. Contact your local
building or fire officials about restrictions and installation inspection in your area.
!
!
WARNING:
Do not pack required air space (clearance) with insulation or other materials. When non-
combustible building materials contact the body of the oven, the clearances to combustibles are
transferred to those non-combustibles.