Technical Data
Device supply
Rated control circuit supply voltage U
S
24 V DC
Control supply voltage range
20,4 V DC - 26,4 V DC
Rated control supply current I
S
200 mA
Protective circuits
Overvoltage protection
Reverse polarity protection
Digital input in acc. IEC 60947-1 Annex S
Rated actuating voltage U
C
24 V DC
Rated actuating current I
C
7 mA
Switching level
< 6 V („0“/Low-Signal)
>12 V („1“/High-Signal)
Switch-On time typ.
< 20 ms
Switch-Off time typ.
< 20 ms
Maximum switching frequency
2 Hz
AC output
Rated operational voltage range U
e
130 V AC - 500 V AC
Rated insulation voltage U
i
500 V AC
Load current range, see 20 Derating
0,1 - 2,6 A / 0,1 A - 6,6 A
Maximum starting current
35A (2,6 A) / 56A (6,6 A)
Rated conditional short-circuit current I
q
100 kA (coordination type 2,
without additional fuse)
SCCR
100 kA
Trigger characteristic in acc. IEC 60947-4-2
2E, 3E, 5, 10A, 10, 20, 30, 40E
Tripping current
110% Nominal current
Overload cooling time
Dynamic, see tripping curves
100% to 75% (2E, nominal current 1 A)
45 s
100% to 75% (2E, nominal current 3 A)
45 s
100% to 75% (10, nominal current 3 A)
3 min 45 s
100% to 75% (30, nominal current 1 A)
13 min
Thermal capacity
at operation with nominal current
75%
Rated operating current I
e
AC-53a
2,6 A / 6,6 A
Rated operating current Ie AC-51
2,6 A / 6,6 A
Leakage current
0,5 mA
Protective circuits
Overvoltage protection
Varistors
Indication of main button LEDs
Ready for Operation
white
Operation Mode (Forward / Backward)
green
Warning
yellow
Error
red